ACM Family - System Installation & Configuration
A100K10647
4.4.4
ACM-M-D/IP72 / ACM-M-D/IP96
Connectors and terminals for power and external equipment are
accessible at the rear of the ACM-M-D/IP72 and ACM-M-D/IP96
a inets o a ess t e onne tors o en t e a inet oor an s ing
out the AlphaCom exchange frame.
Cable inlets are at the bottom of the cabinet and there is a cable
fastening bar in the lower part. All internal cabling is ready-made from
the factory and routed in cable conducts.
The number of terminals and physical placement of terminals for
o er et may ary a or ing to o tional e ui ment an installation
requirements. See the documentation for the actual project for exact
layout and connections.
4.5 Power Supply
See also
Appendix C – Internal Wiring in System Racks.
4.5.1
ACM-M-A-V2 / ACM-M-D
The ACM-M-A-V2 and ACM-M-D are powered from 230 VAC mains
with automatic switch-over to 230 VAC UPS or 24 VDC emergency
power.
All internal power cabling is ready-made from the factory and routed
in cable conducts.
Connect 230 VAC mains to L and N terminals on the X1 circuit breaker
Connect mains earth to the ground bar
Connect 230 VAC UPS power to L and N terminals on the X2 circuit
breaker if this backup power is used
Connect 24 VDC emergency power to the + and - terminals on the
X3 circuit breaker if this backup power is used
The 230 VAC mains outlet X7 is used for service purposes.
Figure 16
ACM-M-A/D Power connection
Power failure
Three power fail relays are included to indicate the types of failures. Each
relay has a NO/NC switch-over contact to indicate ‘Power good/fail’. The
relays are a ti ate
en t e a tual o er is
i means t at t e
NO contact is closed and NC is open under normal conditions.
- X4 is released if the 230 VAC power fails (mains and UPS)
- X5 is released if the 24 VDC emergency power fails
- X6 is released if the 24 VDC output power from AMC-XE7 fails
4.5.2
ACM-48-V10 / ACM-144-V10 / AACM-144-V10
e ACM- -
ACM-
-
an AACM-
-
are o ere
from 230 VAC mains with automatic switch-over to 230 VAC UPS.
-
As an o tion it is ossi le to eli er t e system ra s it
automatic switch-over to 24 VDC emergency power.
All internal power cabling is ready-made from the factory and routed
in cable conducts.
Connect the 230 VAC mains to L and N terminals on the X1 connector
Connect the UPS power to L and N terminals on the X2 circuit
breaker if this backup power is used
Connect 24 VDC emergency power to the + and - terminals on the
X3 circuit breaker if this backup power is used
e
AC mains outlets
an
are use or ser i e
X3
X2
X1
X4
X5
X6
X7
230 VAC
UPS
230 VAC
mains
24 VDC
+
L
L
N
N
AC fail
DC fail
System fail
Service
outlet
230 VAC
NO
NO
NO
NC
NC
NC
230 VAC
UPS
230 VAC
mains
Screen
Relay,
mains/UPS
24 VDC
Mains fail
Mains fuse
X2
X1
X4
X3
F
1
K
0
+
Service
outlet
230 VAC
NO
NC
P1