19
ACM Family - System Installation & Configuration
A100K10647
4.3.3 Board positions
e AMC-I an A C oar s are al ays mounte in fi e ositions
Line boards are mounted according to customer requirements: ASLT
boards for 6 x 4-wire intercom stations and ATLB-12 boards for 12 x
telephone lines. These boards are inserted from the lowest number
positions upwards.
en C relay onta ts are re uire AS oar s must e
mounted in dedicated positions.
I t e CI an au io in uts rom t e A C oar are use t ey ill
substitute the last line board on the last LCM module.
BOARDS
BOARD POSITIONS
Type
Board Name
Part Number
XE7
XE20
XE26
APC
Program and Clock
100 9301 000
-
26
26
AMC-IP
AlphaCom Module Controller
100 9202 100
7
25
25
ASLT
6 Subscriber Lines
100 9101 010
1-6
-
1-19
6 RCO relay contacts used
100 9101 010
2
ATLB-12
12 Telephone Lines
100 9104 000
1-6
-
1-19
Table 2 Board Positions
Figure 11
Board positions in AlphaCom XE7, XE20, XE26
4.4
Connection Terminals
The ACM-M system is shipped with an ACM Programming and
Cable Reference list. This list shows how the external wiring shall be
connected to the different terminal blocks. See
Section 5
for example.
4.4.1
ACM-M-A-V2 and ACM-M-D
Connectors and terminals for power and external equipment are
accessible at the rear of the ACM-M-A-V2 and ACM-M-D cabinet.
o a ess t e onne tors o en t e a inet oor an s ing out t e
AlphaCom XE7 exchange.
Cable inlets are at the bottom of the cabinet and there is a cable
fastening bar in the lower part. All internal cabling is ready-made from
the factory and routed in cable conducts.
A
P
C
A
M
C
-I
P
(
A
G
A
)
FAN 1
FAN 2
FAN 3
LED
POWER
SUPPLY 2
POWER
SUPPLY 1
POWER
SUPPLY 3
POWER
OUT
GND
wrist strap
26 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1
ASLT or ATLB-12
LCM I
LCM II
LCM III
LCM IV
A
S
L
T
1
R
C
O
1
-6
L
C
M
1
A
S
L
T
2
R
C
O
7
-1
2
ad
d
io
n
a
l r
ela
y b
rd
M
R
B
D
A
S
L
T
1
4 R
C
O
7
9-
84
ad
d
io
n
al
re
la
y b
rd
M
R
B
D
A
S
L
T
8
R
C
O
4
3-
48
ad
d
io
n
a
l r
ela
y b
rd
M
R
B
D
A
S
L
T
1
4 R
C
O
7
9-
84
ad
d
io
n
al
re
la
y b
rd
M
R
B
D
A
S
L
T
7
R
C
O
3
7-
42
L
C
M
2
A
S
L
T
1
3 R
C
O
7
3-
78
L
C
M
3
A
S
L
T
1
9
R
C
O
1
09
-1
14
L
C
M
4
AlphaCom XE26
A
P
C
A
M
C
-I
P
(AGA)
INTERNAL
DC POWER
POWER OUT
26 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9 8 1
ASLT or ATLB-12
MAINS
FUSES
N
C
+
24
V
+
15
V
+
5
V
0V
LCM I
LCM II
A
S
L
T
8
R
C
O
7
9-
84
a
d
d
io
n
al
re
la
y b
rd
M
R
B
D
A
S
L
T
1
R
C
O
1
-6
L
C
M
1
A
S
L
T
7
R
C
O
7
3-
78
L
C
M
2
A
S
L
T
2
R
C
O
4
3-
48
ad
d
io
n
al
re
la
y b
rd
M
R
B
D
AlphaCom XE20
A
S
L
T
A
T
L
B
12
A
T
L
B
12
A
T
L
B
12
A
T
L
B
12
POWER
A
T
L
B
12
A
M
C
-IP
1 2 3 4 5 6 7
AlphaCom XE7
230 VAC UPS
230 VAC mains
Relay mains
24 VDC input
AC fail relay
24 VDC in/out
DC fail relay
Ground bar
X3
X2
X1
X4
X5
X6
X7
Intercom
lines / PA
Phone analog
lines for MP114
Power supply
RCI
Figure 12
Terminals in ACM-M-A-V2
Figure 13
Terminals in ACM-M-D
230 VAC UPS
230 VAC mains
Relay mains
24 VDC input
AC fail relay
24 VDC in/out
DC fail relay
Ground bar
X3
X2
X1
X4
X5
X6
X7
Intercom
lines / PA
Phone analog
lines for MP114
Power supply
RCI
1
1
1
1
1
1
1
1
Diode Rectifier
Ethernet Switch
Injector PoE Switch
Power supply