41
ACM Family - System Installation & Configuration
A100K10647
CCoIP
or
SIP
stations are selected by checking the appropriate box.
Checking the
CCoIP Station
o results in a fiel or MAC a ress
and a box for registration with directory number.
- The latest ACM version can use both methods for identifying an IP
station.
en onfiguring an I station in Al a ro you must sele t
i
methods to use to identify the IP station. The advantage of using
registration by directory number is that it is easier to replace the station
at a later stage as this does not require new settings in AlphaPro.
Directory Number registration
- This is the default registration for CCoIP stations.
- Check the
Reg. w/Directory Number
box to register the station.
MAC address registration
- Uncheck the
Reg. w/Directory Number
box to bring up the MAC
a ress fiel
- Enter the station’s MAC address.
The MAC address can be found by logging into the web interface of
the IP station or AlphaWeb under
System Monitoring
>
Stations
>
Unconfigured
.
SIP Station
Check the
SIP Station
box if the station is a SIP telephone.
Group Access Level
Used to specify which group and PA calls a user may make. Each
grou use or grou an A alls ill a e an asso iate
Group
Access Level
. The levels are
Low, Medium
and
High
. The user must
have a higher or the same group access level.
y e ault t e grou use or emergen y A announ ements are
programmed as Group 1 with group access level
High
. Only users with
group access level
High
can make an emergency PA announcement.
Call Setup Priority
Used to specify how outgoing calls from the station shall be treated.
Priority
Low
Medium
High
Alarm
Call to an i le o en
station
Rings
Connects
Connects
Connects
Call to station with
private switch ON
Rings
Rings
Connects
Connects
Call to a station with
absence message
Hears the
message
Hears the
message
Connects
Connects
Call to a busy
station
Busy tone
Busy tone
Busy tone
Connects
Table 10 Call Setup Priority
Call Setup Priority
is used to give special treatment to users that
s oul ne er re ei e a usy tone su as t e ri ge station an
captain’s station.
Volume
Setting se to om ensate or olume loss on long lines an to tune
volume level according to marine requirements.
Available values are -14 dB to +16 dB. The default setting is 0 dB.
This will be ‘normal’ volume setting in the station. For local regulation of
t e olume use t e olume ontrol on t e station
The exchange must be reset if the volume setting has been changed.