7602040
When assembly of the rail is complete, for lifts with
constant gradient of less than 20°, check the gradient
of the entire rail (maximum permitted error 1°) before
putting the lift into operation (see Fig. 27).
5) POSITIONING THE CHARGING STATION
(if applicable)
-
First position the lift where you wish it to stop. This
applies both to the top and bottom stops and to the
intermediate stops. In the case of the first stop (the
lowest) or last stop (the highest), the aluminium profile
that holds the recharging contacts (Fig. 20a) should
already be fixed to the rail.
- In the case of an intermediate stop, position the stairlift
at the stop and use the biadhesive tape provided to
fix the contact profile to the lower rail so it is centred
with respect to the brushes, see (Fig 20). Respect the
measurements in (Fig. 21) when positioning the profile.
If there is no hole for the power cables to pass through
near the intermediate stop, make a 10 mm diameter
hole as shown in (Fig 21a).
- Insert the charging shoes in the contact profile so that
the negative pole (black wire) is ALWAYS to the left,
FIG.19
FIG.20
FIG.22
FIG.21
and the positive pole (red wire) is to the right (Fig. 22),
when looking at the rail from the rear. The charging
shoes must have the slanting side (Fig.22.a) facing so
that the contacts on the carriage can easily slide onto
them. Slide the charging guide shoes along the profile
to centre them perfectly with the brushes.
23
c
d
b
a
c
f
e
d
a
a
a
+
-
15
300
Ø10
20
31
Summary of Contents for V65 B.C.
Page 44: ...44 7801186 CARRELLO INFERIORE...
Page 47: ...47 7801187 TELAIO...
Page 50: ...50 7801188 PEDANA...
Page 54: ...54 7801189 BARRE DI SICUREZZA...
Page 57: ...57 7801190 BARRE DI SICUREZZA RETRATTILI...
Page 63: ...63 7801214 1 2 3 4 5 6 8 9 13 7 11 10 12 14 15 CONNETTORI...
Page 65: ...65 7801192 GUIDA...
Page 68: ...68 7801193 1 4 3 3 2 SCHEDA DI CONTROLLO...
Page 72: ...72 7801206 4 2 3 1 5 6 8 7 14 12 11 11 13 9 10 GIUNZIONI GUIDE V65...