47
7602050
FIG.75
FIG.76
Y
Software crash of
the control card
Telephone diagnosis: send a Vimec technician.
On site diagnostics: replace the main card.
NOTE:
If the display is showing anything but the diagno-
stic codes listed it
requires resetting.
Drive the lift off the charge contacts. Turn the main
switch on the unit off for 10 seconds and then back
on.
12) APPENDIX 2
Maintenance
Items required:
-Lubricant –
petroleum jelly
-Cleaning materials
Tools required:
-None
11.1-
Lubricate the rack with a small quantity of pe-
troleum jelly:
a-
Apply a small amount of petroleum jelly at 4 equal-
ly spaced points along the track in the rack recess
(Fig. 75).
b-
Run the lift up and down the track several times to
distribute the lubricant.
11.2-
Lubricate the swivel mechanism with a small
quantity of petroleum jelly:
a-
Remove the seat by unscrewing the retaining bolt
(Fig. 76).
b-
Apply the lubricant to the nylon washer.
c-
Refit the seat and refit the retaining bolt (Fig. 76).
11.3-
Check all of the safety features on the lift as
described in Section 7 of the installation manual.
11.4-
Check that the lift still stops flush with
the top step and adjust as necessary –
see page 25.
11.5-
Sit on the lift and ride it up and down the stairs
several times:
a-
Listen for any unusual noises.
b-
Check for poor ride quality, especially across the
spliced joint.
11.6-
Clean the track.
11.7-
Clean the seat.
11.8-
Clean the power pack.