13F4, 13A4, 13A4.B - 13F7, 13A7, 13A7.B
answers before the set interval elapses, the electronic starts to
count the conversation time.
Enter the new time with buttons
0
+
to
9
WXYZ
. Press
to
confirm the change.
Default: 30 s, minimum value 1 s, maximum value 255 s.
3.0 - Call time
This is the interval of time, expressed in seconds, that the elec-
tronic unit monitors from the moment that a call is answered by
the indoor unit. Once the interval has elapsed, the electronic
unit ends the call. Enter the new time with buttons
0
+
to
9
WXYZ
(in steps of 10 s). Press
to confirm the change.
Default: 120 s, minimum value 10 s, maximum value 2550 s.
3.1 - Self-start time
This is the time, in seconds, of the duration of the self-start func-
tion. Once the interval has elapsed, the electronic unit discon-
nects the indoor unit. Enter the new time with buttons
0
+
to
9
WXYZ
. Press
to confirm the change.
Default: 10 s, minimum value 1 s, maximum value 255 s.
3.2 - Lock time
Activation time of the lock connected between terminals S+ /
S- and +12V / SR.
Enter the new time with buttons
0
+
to
9
WXYZ
. Press
to
confirm the change.
Default = 1 s, minimum value 0 s corresponding to lock
always off, maximum value 255 s.
3.3 - Function 1 time
Activation time of the device connected between ter12V
/ F1. Enter the new time with buttons
0
+
to
9
WXYZ
. For the mini-
mum value of 0.5 seconds. enter
0
+
. Press
to confirm
the change.
Default = 1 s.
3.4 - Function 2 time
Activation time of the device connected between ter12V
/ F2. Enter the new time with buttons
0
+
to
9
WXYZ
. For the mini-
mum value of 0.5 seconds. enter
0
+
. Press
to confirm
the change.
Default = 1 s.
3.5 - D.O. (door open) send time
Normally an entrance panel sends over the bus a notification
of the D.O. (Door Open) input status only when it changes. The
Master entrance panel sends the global status (
at least one door
is open
or
all the doors are closed
) only when it changes. In
some situations it is desirable for this to be done periodically.
Using buttons
0
+
to
9
WXYZ
enter the send time in minutes.
0
+
to disable. Press
to confirm the change.
Default = 1 minute, 1' minimum, 90' maximum
3.6 - External volume
THIS is the voice volume of the speaker attached to the elec-
tronic unit, which can be adjusted through 8 steps. Press
to enable changes to the volume setting. Press the
buttons to increase or reduce the volume. Press
to confirm
the change.
Default = 3
3.7 - Internal volume
THIS is the volume of the speaker fitted to the electronic unit,
which can be adjusted through 8 steps. Press
to enable
changes to the volume setting. Press the
and
buttons
to increase or reduce the volume. Press
to confirm the
change.
Default = 3
3.8 - Balance
THIS
adjusts the audio compensation on 16 levels between
the input channel and output channel (in order to eliminate any
possible Larsen effect). Press
to enable changes to the
volume setting. Press the
and
buttons to increase or
reduce the volume. Press
to confirm the change.
Default = 8
3.9 - Chimes volume
THIS is the volume of the chimes attached to the electronic
unit, which can be adjusted through 4 steps. Press
to
enable changes to the volume setting. Press the
and
buttons to increase or reduce the volume. Press
to confirm
the change.
Default = 0
3.10 - Lock interlock
Activation of the lock interlock enables operation of the lock
only when the electronic unit is in call, conversation or self-start
status.
Press
1
to activate the interlock; press
0
+
to deactivate the
interlock. Press
to confirm the change.
Default = No
3.11 - Enabling
R
ONE or more electronic units can be configured in such a way
as to inhibit or enable lock release, F1 and F2 control signals
received from indoor units. Letter
D
is used to indicate the disa-
bled status of Direct control signals transmitted to the electronic
unit. Letter C is used to indicate the enabled status of indirect