30
EN
13F4, 13A4, 13A4.B - 13F7, 13A7, 13A7.B
The following sections describe the possible configurations
of the electronic units using the keypad and display. For all of
them, to confirm the change in configuration, the first line of the
display shows:
In the event of parameter error, the display shows a situation
similar to this:
You can go to the next setting by pressing the
button, to the
previous one with
. Exceptions are those settings that re-
gard the indoor units (for example, the contacts list) or that refer
to a number of sub-configurations (for example, time slots). For
these, with
you go to the indoor unit or to the next sub-
configuration, to reach the end of the previous setting. With the
R
button you skip straight to the previous setting. Settings
that behave in this way are highlighted by the
R
symbol next
to the title.
The
button is used to cancel the change in progress or to
return the electronic unit to rest if there are no pending changes.
1.0 - Message language
Indicates the language used for displaying messages both
during normal use (
user
messages) and for the configuration
of the electronic unit (
technical
messages). To change the set
language, press the number on the keypad corresponding to
the required language as indicated in the table or use the arrow
keys.
Button
Language
0
+
Italian
1
English
2
ABC
French
3
DEF
German
4
GHI
Spanish
5
JKL
Portuguese
6
MNO
Greek
7
PQRS
Czech
8
TUV
Dutch
9
WXYZ
Polish
9
WXYZ
Swedish
(Press
9
WXYZ
followed by
)
Press
to confirm the change. The confirmation message
will be displayed in the new language.
Default: Italian
1.1 - Entrance panel ID
Identifies the electronic unit with a code between 1 and 15 [1
and 36]. If the value is 1, the electronic unit is set as
MASTER
,
if the value is between 2 and 15 [2 and 36], the electronic unit
is set as
SLAVE
.
Enter the identification code using buttons
0
+
to
9
WXYZ
. Press
to confirm the change. Confirming the change, the elec-
tronic unit checks the availability of the code. If there is another
electronic unit connected with the same code in the system, the
display will show a message such as this:
and it is necessary to enter another code.
Pressing 0 will “
disable
” the electronic unit temporarily.
Default: 1
Notes:
Do not use ID 15 in the case of a downstream Vertical
installation of a 69RS (69RS.1).
1.2 -
Installation
You choose the installation mode for the electronic unit:
0
+
for Vertical Installation or
1
for Horizontal Installation.
Default: Vertical
Note:
Exiting the configuration and returning the electronic unit
to rest forces sorting the contacts list.
Note:
When going from Horizontal to Vertical installation con-
gruence with other existing settings is checked. If there are any
of them that in the Vertical configuration are no longer valid, the
electronic unit will show this with a message regardless of the
language and with a numerical code:
To confirm the move from Horizontal to Vertical, that in this case
involves automatic deletion of incompatible settings, depress
the
button. With
you cancel the procedure, leaving
the electronic unit in Horizontal mode and without losing the
settings.
1.3 -
Initial ID
This item appears only if the Horizontal configuration has been
selected in step 1.2. It is necessary to indicate the first ID in the
range of the (video) door entry units for which some configura-
tions can be made in the electronic unit. They are: remapping
in the event of non-sequential numbering, contacts list, enabling
use of the lock / F1 / F2, self-starting.
Default: 1