20 - ENGLISH
Dip-switches
1
ON = Transmission of alarm (contact opening) and end of
alarm (contact closing)
1
OFF = Alarm transmission only (contact opening)
2
ON = Selector for configuring the N/C input.
It permits transmitting two different codes to diffe-
rentiate the alarm detected by the infrared sensor from
the one detected by the contact.
2
OFF = Transmission of a single code for both alarms
3
ON = N/C contact input enabled to count 6 pulses (for
roller shutter detectors)
3
OFF = Input enabled for all other types of contact (other
wire magnetic contacts, for instance)
4
ON = In this position the N/C contact is inhibited; for it to
be used, it must be turned OFF
4
OFF = Usable N/C contact
Configuring the detector with magnetic contact 01738
Warning: To configure the magnetic sensor, all the dip
switches must be OFF.
- Prepare the control panel for configuring the radio-frequency
devices (see the control panel manual).
- Open the enclosure.
1 2 3 4