ENGLISH - 19
Funktionsweise
• Moving the magnet away from the body of the sensor (and
moving it nearer) causes radio transmissions for opening
(and closing) the door or window, signalling an alarm (and,
if enabled, the end of the alarm) as a result.
• Opening the contact that may be connected to the N/C
terminal will cause an alarm and end-of-alarm warning as
in the case of the magnet. This signal can be differentiated
(to distinguish between different break-ins) by using the
detector dip-switches.
• The detector LED lights up when an alarm is detected.
• Approximately every 30 minutes, the detector sends a
correctly operating signal to the control panel (via radio
interface).
• Anti-sabotage protection: Opening the battery compart
-
ment causes the tamper alarm;
before changing the
battery it is necessary to set the control panel on
Walktest.
• Walktest: During this phase an alarm is generated so as
to check that the device works properly. In addition, the
control panel identifies the type of detector and provides
an indication on the level of radio reception.
• Flat battery warning: besides the warning on the control
panel, the detector LED blinks.
• The N/C terminal block is self-learning; it is then necessary
for it to remain closed for at least 6 s when inserting the
battery.
Summary of Contents for Arke 19493
Page 2: ......
Page 12: ...10 ENGLISH Connections 1 2 3 4 6LR61 9V 1 2 3 4 Connection example N C contact...
Page 19: ...ENGLISH 17 Connections 1 2 3 4 6LR61 9V 1 2 3 4 N C contact...
Page 31: ...ENGLISH 29 Connections Trimmer for adjusting the loudness of the beeps Battery pack connector...
Page 36: ......
Page 37: ......