Connections

3.2 Outputs

The outputs connector is of the type JST PHR-9.

30 cm 

The outputs are non-polarised solid state (volt-free contact) and are all referred to the common on pin 9.
The outputs can be used to control signals but are not suitable for controlling loads (for example, thee coils of large relays or contactors, high-power LED lights, etc.).

• Wiring.

Output 1 (Orange)
Upper left pushbutton 

Output 2 (Yellow)
Lower left pushbutton 

Output 3 (Green)
Upper centre pushbutton 

Output 4 (Blue)
Lower centre pushbutton  

Output 5 (Purple)
Upper right pushbutton 

Output 6 (Grey)
Lower right pushbutton 

Output 7 (White)
Proximity sensor 

Output 8 (Black)
Do not connect

Pin C (Red)
Outputs common

Output 7 activates when the proximity sensor is tripped.

Summary of Contents for 21126

Page 1: ...21126 Electronic control with 8 inputs 7 outputs 3 modules Installer manual...

Page 2: ...2...

Page 3: ...s 10 4 1 RGB LEDs 10 4 2 Push buttons 10 5 Configuration of the device 11 5 1 Setting the colours of the LEDs 11 5 2 Device setup 11 5 3 Factory reset 12 6 Operation 13 6 1 Display of load status feed...

Page 4: ...hange the current colour settings of the LEDs Outputs Voltage that can be controlled by the outputs 40 V Current that can be controlled by each individual output 100 mA 3 Connections N B The conductor...

Page 5: ...om the device s supply voltage by functional isolation non reinforced this allows the connection of input signals with reference voltages that differ from the supply voltage of the 21126 control provi...

Page 6: ...C IN O1 O2 O3 O4 O5 O6 O7 NC C OUT OUTPUTS V V I1 I2 C IN Example 3 Connection with a signal generator with different voltage references The inputs can be connected directly to a third party device th...

Page 7: ...loads for example thee coils of large relays or contactors high power LED lights etc Wiring Output 1 Orange Upper left pushbutton Output 2 Yellow Lower left pushbutton Output 3 Green Upper centre push...

Page 8: ...ply negative 9 32V 100mA INPUTS I2 I4 I6 I8 NC NC I1 I3 I5 I7 NC C IN O1 O2 O3 O4 O5 O6 O7 NC C OUT OUTPUTS O1 O2 V V C OUT UPPER LEFT PUSHBUTTON OUT 1 LOWER LEFT PUSHBUTTON OUT 2 UPPER CENTRE PUSHBUT...

Page 9: ...with characteristics compatible with the maximum voltage and current values of the 21126 control The outputs common is to be connected directly to the power supply positive 9 32V 100mA INPUTS I2 I4 I...

Page 10: ...dis played on the cover plate 21663 can be customised using the specific labels 4 2 Pushbuttons When the cover plate is not fitted the 21126 control presents six physical pushbuttons shown in blue and...

Page 11: ...s not activated or if the signal provided has a pulse width modulation of less than 14 the colours of the LEDs may be set using the following procedure 1 Long press the upper configuration button the...

Page 12: ...guration procedure without saving any changes made Example The device illustrated below is set to low sensitivity and when in standby the LEDs illuminate with minimum brightness 5 2 2 Setup with rocke...

Page 13: ...ll remain activated for 60 s or until one the two pushbuttons is pressed again If a change of direction is commanded when the blind is moving both the corresponding outputs remain off for 500 ms befor...

Page 14: ...ste at the end of its working life The user must take the worn product to a sorted waste center or return it to the retailer when purchasing a new one Products for disposal can be consigned free of ch...

Page 15: ...Viale Vicenza 14 36063 Marostica VI Italy www vimar com 21126IEN 02 1901...