Connections
3.2 Outputs
The outputs connector is of the type JST PHR-9.
30 cm
The outputs are non-polarised solid state (volt-free contact) and are all referred to the common on pin 9.
The outputs can be used to control signals but are not suitable for controlling loads (for example, thee coils of large relays or contactors, high-power LED lights, etc.).
• Wiring.
Output 1 (Orange)
Upper left pushbutton
Output 2 (Yellow)
Lower left pushbutton
Output 3 (Green)
Upper centre pushbutton
Output 4 (Blue)
Lower centre pushbutton
Output 5 (Purple)
Upper right pushbutton
Output 6 (Grey)
Lower right pushbutton
Output 7 (White)
Proximity sensor
Output 8 (Black)
Do not connect
Pin C (Red)
Outputs common
Output 7 activates when the proximity sensor is tripped.