Check for continuity between the hot and neutral terminals and the pump’s motor
casing. If continuity is found, replace the circulation pump.
•
Check current draw. Typical current draw will be .36 amp without pump
resistance. If excessive current draw is found, check the pump’s impeller for
foreign particles or severe build-up of mineral deposits.
Removal
1.
Disconnect power to the icemaker.
2.
From inside the unit, remove the escutcheon panel.
3.
Remove the grid-cutter (see section 6.1).
4.
Remove the ice deflector.
5.
Remove the reservoir (see section 6.2)
Figure 6.6
6.
Unplug the circulation pump at the receptacle at the top of the circulation pump (see
figure 6.6).
7.
Disconnect the water line at the circulation pump (see figure 6.6).
8.
Remove the two screws that secure the circulation pump (see figure 6.6).
9.
Remove the circulation pump.
Installation
Reverse the removal procedure for installation.