2.
Plug the grid-cutter into the receptacle on the side of the liner. Route the plug wire
between the reservoir and liner (see figure 6.1). This will keep it away from the
path of the ice slab.
3.
Re-install the escutcheon panel. Adjustment to the brackets may be necessary to
align the escutcheon panel.
6.2 Reservoir
The reservoir retains the water needed to produce an ice slab. It will hold a maximum of
3 quarts of water. Anything over 3 quarts will be drained in the reservoir’s overflow.
Anytime the reservoir is removed, it should be cleaned with ice machine cleaner. Be sure
to rinse the reservoir before re-installing.
To remove the reservoir:
1.
From inside the unit, remove the escutcheon panel.
2.
Remove the grid-cutter (see section 6.1).
3.
Remove the four screws that secure the ice deflector.
4.
Remove the ice deflector.
5.
Drain the reservoir by removing the drain plug located on the bottom of the
reservoir.
6.
Remove the two screws and spacers that secure the reservoir (see figure 6.2)
7.
Remove the reservoir by lifting the drain tube off the reservoir and away from the
circulation pump (see figure6.3).
Figure 6.2
Gently lift reservoir off drain tube (figure 6.3),
than lower the reservoir to clear the circulation
pump.
Figure 6.3