1.2 SERIAL NAMEPLATE
The serial nameplate is located on the bottom flange directly above the grille on all units.
VIKING 15 INCH ICE MAKER
SERIAL NUMBERS
V 00 00 00 12345
Viking
Production Control
Month of Year
Calendar Year
Week Ending Date
1.3 BEFORE SERVICING
•
Power to the icemaker must be off before any attempt to service. This can be
done by unplugging the unit or disrupting power to the icemaker receptacle.
Verify power is disconnected to unit.
•
If unit has been running, use caution around condenser and copper tubing. These
areas may be very hot.
•
Use caution around condenser fins and base-plate edges. These areas can be
sharp.
•
Refrigerant is under high pressure. Evacuate system before attempting to open
refrigerant system.
•
Reasonable care and safe work methods should be practiced when working on the
icemaker. Do not work with energized electrical equipment in wet or damp
areas.
•
Use an appropriate work area and location when performing repairs. You will
find that it is easier to perform work on the icemaker if set on a raised platform or
work table.
•
Wear protective safety glasses when performing any kind of work.
•
Any refrigerant, whether CFC, HCFC, or HFC (R-12, R-22 or R-134A) must be
recovered. Federal regulations prohibit the intentional venting or release of
refrigerants during the service repair or disposal of an appliance.
5