9
RANGETOP CUTOUT and SPECIFICATIONS
1.
Gas Line Requirements:
a. Gas pipe size should be 3/4" (½" inside diameter)
b. Gas pipe should be 3" or less from floor and 6" from left to center of unit to allow for the
flex
line.
i.e.
30" range 6"-15" from left
48" range
6"-24" from left
36" range 6"-15" from left
60" range
6"-30" from left
If it is higher than 3" from the floor, the range will not fit flush against the wall and
The shutoff valve will not be accessible.
2. Electrical
Requirements
: Gas ranges, gas rangetops, and Gas cooktops require a 120 volt
electrical outlet (GFI ground fault outlet not recommended).
a. 3" or less from the floor and 6" from the right to center of the unit.
i.e.
30" range 6"-15" from right
48" range
6"-24" from right
36" range 6"-18" from right
60" range
6"-30" from right