background image

 

 18 

GRILL / GRIDDLE BURNER ADJUSTMENT 

 

GRILL ( Item “A” ) 

 
1.  The grill burner orifice and air shutter are located 

beneath the front end of the grill assembly.  To 
gain access to the adjustments, remove the grill 
grate, grate support, flame spreader and the burner 
shield. 

2.  Remove the screw at the front and rear of the 

burner. 

3.  Lift the burner off the orifice and locate the air 
 

shutter adjustment screw at the end of the burner. 

4.  Loosen the screw and adjust the air shutter to the  

desired setting (for natural gas open shutter 
approximately ½"; for LP/Propane gas open the air 
shutter approximately 9/16"). 

5.  Tighten the screw, then replace burner on the 
orifice. 
6.  Check flame for desired height before replacement 
         of the above parts. 
7.  The flame adjustments are the same as the surface  

burners.  Use a ½" deep socket to adjust the orifice 
hood on natural gas only (LP tightened to the fixed  
orifice); turn clockwise to decrease the flame and  
counter clockwise to increase the flame. 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 

GRIDDLE ( Item “B” ) 

 
1.  To gain access to the burner orifice and air shutter,  

remove grates and grate supports located on either 
side of the griddle.  Lift and remove griddle plate. 

2.  Carefully remove ignitor and put to the side. 
3.  Remove the metal plate located below the burner. 
4.  Remove the screws at the front and rear of the 
 

burner remove the burner tube and locate the air 

 

shutter adjustment screw at the end of the burner 

 tube. 
5.  Flame adjustments are the same as the grill - see #4 

and #7 under grill. 

6.  Replace the griddle plate. 

Summary of Contents for VGR30

Page 1: ...SERVICE MANUAL FREE STANDING GAS RANGE...

Page 2: ...ontrol Panel Removal 23 Landing Ledge Removal 23 Component Location 24 Top Burner Removal 25 Top Burner Ignitor Removal 25 Spark Module Removal 25 Indicator Light Removal 26 Bake Broil Thermostat Remo...

Page 3: ...o White Standard Range 30 W FG Forest Green SC 27 D PL Plum Convection Range 30 W SS Stainless Steel VB Viking Blue RC 27 D WH White Convection Range 36 48 W GG Graphite Gray RT 24 D LN Linen Rangetop...

Page 4: ...4...

Page 5: ...S 5 YEAR ANY HALOGEN ELEMENT BAKE ELEMENT BROIL ELEMENT OR CONVECTION COOK ELEMENT PART ONLY GAS WALL OVENS 90 DAYS GLASS PAINTED PORCELAIN AND DECORATIVE ITEMS 1 YEAR FULL WARRANTY COMPONENTS AND ACC...

Page 6: ...VAPORATOR CONNECTING TUBING 12 YEAR LIMITED WARRANTY SEALED SYSTEM COMPONENT PART ONLY COMPRESSOR CONDENSER DRYER STRAINER EVAPORATOR CONNECTING TUBING WINE COOLER 90 DAYS PAINTED OR DECORATIVE ITEMS...

Page 7: ...2 The range CANNOT be installed directly adjacent to sidewalls tall cabinets tall appliances or other side vertical surfaces above 36 high There must be a minimum of 6 side clearance from the range t...

Page 8: ...use with natural gas The orifice hoods must be screwed snug when LP Propane is used See LP Propane conversion d Manifold pressure should be checked with a manometer natural gas requires 5 0 WC and LP...

Page 9: ...m left 60 range 6 30 from left If it is higher than 3 from the floor the range will not fit flush against the wall and The shutoff valve will not be accessible 2 Electrical Requirements Gas ranges gas...

Page 10: ...er trim on the 2 door models to adjust the leveling legs A Right Side Front Back Adjustable Legs B Left Side Front Back Adjustable Legs When adjusted properly this space will be uniform from the top t...

Page 11: ...of primary and secondary air are needed for quiet and efficient appliance operation and for complete combustion of the gas Size of the inlet openings and flue outlets control secondary air flow E Expl...

Page 12: ...of aldehydes is present then carbon monoxides almost always will be present aldehydes themselves also are toxic H GAS BURNER OPERATION A gas burner is a device to burn gas under control to produce us...

Page 13: ...nd 100 000 BTU hr use pipe or 1 4 tubing From d to e demand 35 000 BTU hr use pipe or tubing From b to f demand 200 000 BTU hr use 3 4 pipe From c to g demand 38 000 BTU hr use pipe or 5 8 tubing From...

Page 14: ...hoods clockwise until they become snug against the internal LP Propane pin orifice See Illustration 2 After adjusting the oven burner orifice hoods Illustration 3 Item 3 for LP gas it may be necessary...

Page 15: ...shut off valve 2 Removing the range from the cabinets 3 Remove the back guard from the range 4 Locating the gas supply line at the end of the broiler venturi 5 Remove and replace the orifice spud loc...

Page 16: ...ts on the burner at the burner ports a Open the air shutter gap to eliminate yellow tipping BURNER ASSEMBLY b Close the air gap to prevent a noisy flame that lifts off the burner ports 8 Turn the surf...

Page 17: ...flame height adjust the air shutter illustration 1 item 1 to obtain a blue flame with no yellow tipping that contacts the burner at the burner ports a Open the air shutter gap illustration 1 item 1 to...

Page 18: ...fice 6 Check flame for desired height before replacement of the above parts 7 The flame adjustments are the same as the surface burners Use a deep socket to adjust the orifice hood on natural gas only...

Page 19: ...sure should never exceed 14 WCP or 1 2 PSI E Be sure the thermostat bulb is straight and properly spaced from the oven liner The sensor bulb clips should be in place F Place a weighted thermo couple i...

Page 20: ...ostat wiring removed when checking the contacts for continuity Access to the thermostat contacts can be made by removing the control panel Replace the thermostat if the switch contacts are defective T...

Page 21: ...e lead of the ignite or any amprobe attached to the of the ignite will check the amount of current flowing through the ignite circuit With the oven turned on and the ignite glowing red a current readi...

Page 22: ...olds hinge in place while removing or replacing the door C DOOR HINGE SPRING Color denotes part number b Grasp the door near the lower end c Place your thumbs over the door socket openings to prevent...

Page 23: ...ding C Door Handle Bracket D Door Handle E Outer Door Glass Retainer F Heat Baffle G Insulation 32 x 16 7 8 H Inner Door Glass Retainer J Inner Door Glass 3 Door handle is mounted to the door panel an...

Page 24: ...rill models 4 Remove two decorative screws at both ends of the control panel 5 It is not necessary to remove bezels LANDING LEDGE REMOVAL 1 Shut off power to the unit 2 remove the control panel See co...

Page 25: ...25 COMPONENT LOCATION...

Page 26: ...bly TOP BURNER IGNITOR REMOVAL 1 Shut off power to the oven 2 Remove grate and burner bowl 3 Remove two 2 screws securing the ignitor to the burner support 4 Disconnect the ignitor wire SPARK MODULE R...

Page 27: ...nect the wire leads to the ignitor 5 Remove the oven burner See oven burner removal 6 Remove two 2 screws securing the ignitor to the burner and remove the ignitor BROIL GAS VALVE REMOVAL 1 Shut off p...

Page 28: ...EAKS USING A SOAP SOLUTION AFTER INSTALL REPLACEMENT REGULATOR USE SEALANT ON ALL PIPE JOINTS SEALANT MUST BE RESTIVE TO L P GAS DO NOT USE THREAD TAPE CONVECTION FAN REMOVAL 1 Shut off power to the u...

Page 29: ...up and the indicator does not light replace the indicator OVEN LIGHT SWITCH The oven light switches are mounted in the control panel The light switch can be checked for continuity by using an ohmmete...

Page 30: ...move the grates burner bowls and grate supports on either side of the griddle Lift and remove the griddle 3 Remove two 2 securing the ignitor to the griddle box Disconnect the wiring from the ignitor...

Page 31: ...ated check for broken wiring between the gas valve and thermostat 3 No broil operation Bake 3A Defective thermostat 3 A Check thermostat contacts for continuity operates normally Broil contacts or che...

Page 32: ...h 7B Check light switch contacts for continuity 7C Defective light socket 7C Check for 120VAC the light socket terminals If voltage is present replace the light socket If no voltage is present check f...

Page 33: ...r a dirty orifice 14D Clean orifice or replace faulty drilled orifice 15 Lifting flames flames rise 15A Lifting burner flames results 15A Reduce primary air from the ports to burn some when the flow v...

Page 34: ...ck gas pressure Blowing lifting Flames Normal Hard Flames Yellow Tipping Yellow Flames Check the gas supply and set the regulator to the proper supply of gas A properly adjusted burner should be stabl...

Page 35: ...35 GRIDDLE REPAIR KIT FOR 12 VIKING RANGETOP ONLY...

Page 36: ...36 GRIDDLE REPAIR KIT FOR 24 VIKING RANGETOP ONLY...

Page 37: ...37...

Page 38: ...38...

Page 39: ...38...

Page 40: ...on Data Microsoft Templates Normal dot Title Subject Author Viking Range Keywords Comments Creation Date 7 9 2001 6 19 PM Change Number 3 Last Saved On 3 28 2003 3 40 PM Last Saved By Ken Sievert Tota...

Reviews: