background image

2-EN

Converting the Bake Burner

1.

Remove oven racks and oven support.

2.

Remove oven bottom.

3.

Remove screws securing bake igniter to bake burner.

4.

Remove screws securing bake burner shield to oven burner box.

5.

Remove screws securing bake burner to oven burner box.

6.

Loosen air shutter screw and adjust opening on burner to 3/8”

 

and tighten air shutter screw.

7.

Remove orifice by turning counterclockwise and replace with

 

orifice 1.68 from bag labeled. 

Important: The orifice tip must be located 3/16” inside the burner
for proper gas mixture and combustion. The depth of the orifice
can be adjusted by turning the orifice counterclockwise (more
depth) or clockwise (less depth). Reverse procedure as needed to
reassemble.

Converting the Broil Burner

1. Remove the screws (4) from the broiler baffle.
2. Carefully remove the broiler burner
Note: Pay close attention to the igniter wire while removing the
broiler burner.

3.

Disconnect the igniter wire.

4.

Use a 1/2” wrench to remove the broiler burner natural gas

 

orifice hood and replace with LP broiler burner hood 1.03.

5.

Reinstall the converted broiler burner by first firmly attaching 

the igniter wire.

6. Reposition the broiler burner in its original position.
7. Replace the four screws into the broiler baffle.

Air Shutter Settings for Broiler Burner

1. Use a screwdriver to loosen the air shutter screw.
2. Adjust the air shutters for LP gas by rotating the shutter to the

fully open position. Your final settings may vary.

3. Retighten the air shutter screw.
Bake and broiler flame must be checked with the door closed to

properly check flame characteristics.

4. Turn on the gas.
5. Turn on the electricity.

6. Retighten the air shutter screw.
7. Turn on the bake and broiler burner.
8. As you watch the flame with the oven door closed, check the

following through the oven door window:

a. If the flames are yellow, open the air shutter more.
b. If the flames blow away or flutter from the burner, close

the air shutter more.

9. Open the oven door and check the inner cone of the bake

and broiler burner flame. It should be approximately 1/2” to
3/4” long for the bake and broil burners. The combustion
quality of the burner flames needs to be determined visually.
With LP gas, some yellow tipping on the outer cones is
normal.

10. When all adjustments are made and the results are

satisfactory then replace the oven bottom cover.

In some cases, foreign particles in the gas line may cause an
orange flame at first but this will soon disappear.

Note: To convert the oven back to Natural gas, reverse the
instructions given for making the LP gas adjustments.

Note: When the LP/Propane conversion is finished, complete the
enclosed conversion label and place it next to the rating label.

Vo let d 'ai

A ir  Sh u t t e r

A ir  Sh u t t e r
Se t  Sc re w

O r ific e

H o o d

Ad justment

Sc rew

Air Shutter

Adjustment screw

Air shutter

W A R N I N G

If you attempt to measure the inner cone of the
flame, please use caution as burns could result.

Summary of Contents for RLPKR2

Page 1: ...f required 3 Locate the proper LP surface burner orifices included with the kit according to the chart below The orifice stamp can be either the metric diameter size or the orfice drill size 4 Install...

Page 2: ...for LP gas by rotating the shutter to the fully open position Your final settings may vary 3 Retighten the air shutter screw Bake and broiler flame must be checked with the door closed to properly ch...

Page 3: ...red 3 Locate the proper NAT surface burner orifices included with the kit according to the diagram below The orifice stamp can be either the metric diameter size or the orfice drill size 4 Install the...

Page 4: ...rotating the shutter to the fully open position Your final settings may vary 3 Retighten the air shutter screw Bake and broiler flame must be checked with the door closed to properly check flame chara...

Page 5: ...ocalisez les orifices de br leur PL corrects inclus avec l ensemble conform ment la liste ci dessus Le timbre de l orifice peut tre diam tre m trique perceuse ou la taille de foret 4 Installez les ori...

Page 6: ...urnevis pour desserrer la vis du volet d air 2 Ajustez les volets d air pour gaz PL en tournant le volet en position grand ouverte Vos r glages finals pourront varier 3 Resserrez la vis du volet d air...

Page 7: ...ocalisez les orifices de br leur Naturel corrects inclus avec l ensemble conform ment la liste ci dessus Le timbre de l orifice peut tre diam tre m trique perceuse ou la taille de foret 4 Installez le...

Page 8: ...air 2 Ajustez les volets d air pour gaz Naturel en tournant le volet en position grand ouverte Vos r glages finals pourront varier 3 Resserrez la vis du volet d air La flamme de cuisson au four ou du...

Reviews: