17
During outbound SIP calls the Panic Button LED can be programmed to light automatically when the called party has
answered or only light after the called party has entered a touch tone “
”
.
Factory Setting:
Automatic
36. Panic Button LED Control
35. Panic Button LED Mode
The Panic Button LED on the
PB-3-IP
can be programmed to one of four different modes.
Factory Setting:
Emergency Phone Mode
OFF Mode:
Useful for silent monitoring applications. In this mode the Panic Button LED will not light during normal
operation. It will only light (blink) if it cannot register with the programmed SIP server or while manually resetting all
network parameters to factory default.
Entry Phone Mode:
The Panic Button LED will remain ON in the idle state, turn off while button is pressed, blink during
dialing, light steady when the call is answered, then turn OFF momentarily when the call is completed. The panic Button
LED will also turn off when the announcement is playing.
Emergency Phone Mode:
The Panic Button LED will remain OFF in the idle state but will light steady during an
inbound call. During an outbound call, the Panic Button LED will turn on while the button is pressed, blink during dialing,
light steady when the call is connected, then turn off when the call is completed. The Panic Button LED will also turn
off when the announcement is playing.
Emergency Phone Outbound Only:
The Panic Button LED will remain OFF in the idle state and stays off during an
inbound call. During an outbound call, the Panic Button LED will turn on while the button is pressed, blink during dialing,
light steady when the call is connected, then turn off when the call is completed. The Panic Button LED will also turn
off when the announcement is playing. This mode is useful for silent monitoring on inbound calls.
If enabled and a busy is detected, the
PB-3-IP
phone will dial the next programmed Emergency Phone number. A
momentary press of the Panic button will dial the first programmed Emergency number.
Factory Setting:
Enabled
33. Dial Next Number on Busy
34. Send ID Number as
32. Dial Next Number on Ring No Answer
If enabled and a ring-no-answer is detected, the
PB-3-IP
Phone will dial the next programmed Emergency Phone
number after the programmed amount of rings. A momentary press of the Panic button will dial the first programmed
Emergeny number.
Factory Setting:
7 (will redial after 7 rings)
The I.D. number can be transmitted as RFC 2833 or as In-Band DTMF.
Factory Setting:
RFC 2833