15
13. Relay Internal / External
With the relay set to “Internal” the
VoIP Tower Phone
will activate its on board relay for door strike / gate control. The
Relay should be set to “External” for higher security installations when using a Viking remote model
RC-4A
relay
controller to activate the door strike / gate controller (see DOD 582).
Factory Setting:
Internal
14. Relay Mode
Doorstrike Mode.
When programmed for Doorstrike Mode the relay will momentarily activate for the preprogrammed
relay activation time after detecting the correct relay activation command (one or two digit touch tone) from the called
party.
Outbound Call Mode.
When programmed for Outbound Call Mode the relay will activate continuously for the duration
of any outbound call from the Emergency/Entry phone. This mode is useful for activating strobe lights for Emergency
VoIP phones.
Inbound/Outbound Call Mode.
When programmed for Inbound/Outbound Call Mode the relay will activate
continuously for the duration of any inbound or outbound call to or from the Emergency/Entry phone. This mode is
useful for turning on IR flood lights, VoIP phones with cameras, etc.
Doorbell Mode.
When programmed for Doorbell Mode the relay will momentarily activate the relay for the
preprogrammed relay activation time on any outbound call from the Emergency/Entry phone. This mode is useful for
activating a door chime, etc. When activating door chimes, a 0.5 - 1 second relay activation time is recommended.
LV-1K Control Mode.
When programmed for
LV-1K
Control Mode the relay will activate continuously while the
Emergency/Entry phone is powered and registered to the SIP server. In the event the unit loses power and/or SIP
registration the relay will turn off, activating
LV-1K
’s flashing LED and audible beep signals.
Ring Mode.
When programmed for Ring Mode the relay will continuously activate while the ringing extension is called.
This mode is useful for activating a Viking model
SL-2
strobe light, etc.
Ring Flash Mode.
When programmed for Ring Flash Mode the relay will momentarily turn on and off in a 400ms
on/off cadence while the ringing extension is called. This mode is useful for activating a Viking
LPL-1
Remote Visual
Indicator, etc.
Factory Setting:
Door Strike