background image

22

Related Products

ADA Compliant VoIP Emergency Phones with 

Built-In Dialer and Digital Voice Announcer

The 

1600-IP Series

ADA Compliant VoIP Emergency Phones are designed

to provide quick and reliable handsfree communication for SIP VoIP phone
systems with PoE.  All 

1600-IP Series

phones meet ADA requirements for

elevator/ emergency telephones, and can be programmed from any Touch
Tone phone or PC on the same LAN. The phones can dial up to 5
programmable emergency numbers. In addition, the 

E-1600-20-IP, E-1600-

22-IP

E-1600-52-IP 

and 

E-1600-TP2IPEWP 

feature a second "

INFO

" button

that will dial up to 5 non-emergency numbers.

The 

1600-IP Series

phones can be programmed to automatically deliver a

digital announcement to identify the location of the emergency call.
Alternatively, a DTMF Touch Tone code may also be delivered.  A “Call
Connected” LED can be initiated manually or automatically.  All programming
parameters, including phone numbers and location numbers, are stored in
non-volatile memory, requiring no batteries.  All units are PoE powered.

For outdoor installations where the unit is exposed to precipitation or
condensation, select 

1600-IP Series

phones are available with Enhanced

Weather Protection (

EWP

).  EWP products feature foam rubber gaskets and

boots, sealed connections, gel-filled butt connectors, as well as urethane or
thermal plastic potted circuit boards. For more information, see

DOD 859

.

E-1600-IP            E-1600-45-IP         E-1600-60-IP        E-1600-65-IP

E-1600-20-IP        E-1600-22-IP

E-1600-30-IP         E-1600-32-IP

E-1600-50/52-IP

E-1600-53-IP

E-1600-55-IP           E-1600-03-IP

E-1600-02-IP/E-1600-TP-IPEWP

E-1600-TP2IPEWP/E-1600-GT-IPEWP

Summary of Contents for E-1600-ASTIPEWP

Page 1: ...P ADA Compliant VoIP Emergency Tower Phones are designed to provide quick and reliable handsfree communication for SIP VoIP phone systems with PoE The tower phones meet ADA requirements for emergency...

Page 2: ...6 2 9 or earlier Avaya IP Office Platform BlueBox Brekeke Cisco Unified Communications Manager CUCM Cisco Unified Communications Manager Express CUCME Elastix epygi QX200 4 Freeswitch Grandstream 4 In...

Page 3: ...ransport Protocol is an Internet protocol standard that specifies a way for programs to manage the real time transmission of multimedia data over either unicast or multicast network services Server A...

Page 4: ...aceplate Marine grade 316 stainless steel Speaker Mylar speaker with rubber gasket to maintain water tight seal and eliminate water deterioration Mounting Screws 4 T 10 Torx head stainless steel flat...

Page 5: ...be Panel Attention To make sure water drain notch between stobe and panel is facing down attach strobe panel with wire exiting left side of panel Step 1 Mount the tower phone approximately 42 above th...

Page 6: ...one of 4 different Flash Patterns can be programmed for the strobe see Strobe Flash Patterns on page 7 Note The SL 2 is factory default programmed as a steady on beacon with a single flash strobe when...

Page 7: ...g through 6 different beacon brightness settings from lowest to highest When the SL 2 lights at the desired beacon brightness level immediately remove the Green wire from the Black The SL 2 should fla...

Page 8: ...ions of Windows Adobe Acrobat Reader 8 or higher VoIP Tower Phone hardware Available LAN with PoE class 1 4 Watts Ethernet cable CAT5 min 1 MB minimum free hard drive space for installation 16MB of fr...

Page 9: ...g you to trouble shoot the failure A Connect Disconnect Open the Viking IP Programming software on the PC and the start screen shown below will appear Any Viking IP phones that are connected to the ne...

Page 10: ...ogramming settings Step 5 Click on the IP Settings tab Step 6 Select the appropriate value Static IP Settings or DHCP for Set Unit IP Address via Note changing the IP address will cause you to have to...

Page 11: ...ting the LAN Cable RJ45 plug Step 2 Press and hold the call button then reconnect the LAN Cable RJ45 plug Step 3 Continue to hold Call button until you hear 2 beeps approximately 6 seconds Then releas...

Page 12: ...16 Microphone Volume 0 9 0 Auto factory set to 5 23 17 Talk Listen Delay VOX 0 1 0 9 seconds factory set to 0 5 seconds 24 17 In Band Audio Call Progress Enabled Disabled factory set to Enabled 25 17...

Page 13: ...the Register Fails drop down box NOTE The maximum length of the SIP server address is 75 characters 6 Register Fails Re Resolve or Alternate Server 4 Outbound Proxy If your SIP provider requires an ou...

Page 14: ...or stereo 2 Sampling rates of 8k 16k or 32kHz are acceptable 3 The WAV file may be stereo or multi channel but only the Left Channel will be loaded 4 When saved wave files will be converted to 8KHz m...

Page 15: ...o or from the Emergency Entry phone This mode is useful for turning on IR flood lights VoIP phones with cameras etc Doorbell Mode When programmed for Doorbell Mode the relay will momentarily activate...

Page 16: ...essing the button again after the call has been initiated will not terminate the call Factory Setting Enabled 19 Alternating Switch Action Panic Button Mode When set to Ring or Ring with AGC The E 160...

Page 17: ...wer limit or touch tone to hang up Factory Setting 3 minutes 29 Call Length Timeout This feature selects switching time between talk and listen modes VOX switching time The Talk Listen Delay can be pr...

Page 18: ...re options for auto answer require the callers to dial the access code in order to transmit a page activate the relay or activate the optional RC 4A relays Factory Setting Auto Answer Disabled Inbound...

Page 19: ...ferent modes Factory Setting Entry Phone OFF Mode Useful for silent monitoring applications In this mode the LED will not light during normal operation It will only light blink if it cannot register w...

Page 20: ...rm 39 IP Firmware If new VoIP Tower Phone firmware is available after opening the programming software a pop window will come up asking you if you would like to update firmware An alternative method o...

Page 21: ...l know the location of the emergency call by either the voice announcement or by decoding the touch tone I D number Once the Call Connected LED is on the key can be used to force the phone to hang up...

Page 22: ...uncement to identify the location of the emergency call Alternatively a DTMF Touch Tone code may also be delivered A Call Connected LED can be initiated manually or automatically All programming param...

Page 23: ...s products to be free from defects in the workmanship or materials under normal use and service for a period of two years from the date of purchase from any authorized Viking distributor If at any tim...

Reviews: