![Viking Designer DEDO530T Service Manual Download Page 63](http://html1.mh-extra.com/html/viking/designer-dedo530t/designer-dedo530t_service-manual_1023514063.webp)
Diagnostics
© 2008 Viking Preferred Service
63
BROIL
(Outer)
When the Main Control Board calls for the Outer Broil element, K13 is energized.
FIG A
shows the K13 relay
activated.
FIG B
shows a close-up of the P6 connector. L1 (Red) comes into the P6 connection on the relay
board. With the relay closed, L2 is sent to the Outer Broil element. The Outer Broil element draws 6 amps. As
with the Inner Broil, the K17 line break relay must also close to provide L2 to the Outer Broil element.
CONVECTION
When the Main Control Board calls for the Convection element, K14 is energized.
FIG A
shows the K14 relay
activated.
FIG B
shows a close-up of the P7 connector. L1 (Red) comes into the P7 connection on the relay
board. With the relay closed, L2 is sent to the Convection element. The Convection element draws 11.5 amps.
As with the Outer Broil, the K17 line break relay must also close to provide L2 to the Convection element.
K10 K11 K12 K13 K14
K10 K11 K12 K13 K14
From Main Terminal
Block L1
To Outer Broil
element
K10 K11 K12 K13 K14
K10 K11 K12 K13 K14
From Main Terminal
Block L1
To Convection
element
Note: On the Première Double oven
models, the lower oven P7 wire is white
w/ green tracer
Summary of Contents for Designer DEDO530T
Page 31: ...Diagnostics 2008 Viking Preferred Service 31...
Page 32: ...Diagnostics 2008 Viking Preferred Service 32 Broil cycle chart TruConvec cycle chart...
Page 33: ...Diagnostics 2008 Viking Preferred Service 33 NOTE Convection fan is running at LOW speed...
Page 37: ...Diagnostics 2008 Viking Preferred Service 37...
Page 71: ...Wiring and Schematics 2008 Viking Preferred Service 71...
Page 72: ...Wiring and Schematics 2008 Viking Preferred Service 72...
Page 73: ...Wiring and Schematics 2008 Viking Preferred Service 73...