35
Diagnostics
Service Tests (continued)
213 Ice Compartment Temperature Offsets
Press the “UR” keypad or “LR” keypad to toggle calibration of ice maker compartment temperature plus or
minus 1°F in increments up to + 0 / + 8°F.
Note:
Temperature will read in fahrenheit regardless of what current temperature scale is being used.
221 Reset Default Settings (CAUTION: This will reset all adjustments made prior to this test)
Press the “UR” keypad or “LR” keypad to toggle reset to factory default settings dEF.
231 Water Filter Usage
Display shows the percent water filter consumption since water filter was reset.
100% indicates the filter should be replaced.
Press either
button to
toggle through
test cycles
Press either
button to change
calibration of ice
compartment
temperature plus
or minus in
1˚ increments
2
213
Press either
button to
reset to factory
default (dEF)
Press either
button to
toggle through
test cycles
221
Press either
button to
toggle through
test cycles
231
50%