E.  Keyless Entry Codes and One Time Use Keyless Entry Codes

F.   Operation Commands

Touch tone keyless entry codes may be used by the tenants to provide keyless entry.  Each entry phone may
have up to 6 keyless entry codes. There are also up to 6 master keyless entry codes which can be used at all
four entry locations.  If a keyless entry code has been programmed, an off-hook entry phone is given 4 seconds
of dial tone before ringing the house phone.  During this time a touch tone “

#

” + the “

keyless entry code

” may

be entered.  

A correct keyless entry code will provide a timed door strike activation for that entry phone location. One time use
keyless entry codes function as described above but can only be used 

ONCE

. After the one time use keyless

entry code has been used, it is instantly cleared from the 

C-2000B

’s memory.  This is ideal for issuing keyless

entry codes to service personnel, etc.  

Note:

A short buzz sound indicates when the relay has been activated

and the visitor can now open the door.

See 

Programming 

section

L. Global Keyless Entry

for a description of the Global Keyless Entry feature.

Operation Description

Touch Tone Command

*Activate door strike relay 

Q Q

* Continuously activate (latch) door strike relay 

1

*Continuously de-activate (unlatch) door strike relay 

0

* Toggle relay from last position 

#

Answer or disconnect an entry phone call 

#

Monitor entry phone 1 

#1

Monitor entry phone 2 

#2

Monitor entry phone 3 

#3

Monitor entry phone 4 

#4

CAUTION:  Some strikes are designed for intermittent operation only. The latch and toggle commands
should NOT be used with these intermittent strikes, or damage to the strike may occur. Only use the latch
and toggle commands with strikes designed for continuous operation.

* Notes: 1. 

The activate door strike relay column is shown with the default ”

QQ

” as the door strike activation code.

To change the door strike activation code, see 

Programming 

section 

H. Door Strike Activation Code

.

Note that the remaining three operation commcands ( 

Q

1

Q

0

, and

Q

#

are not programmable

   2.

The latch commands can be disabled (see 

Programming

section 

B

).

3    .

The “toggle relay from last position” command (“

Q

#

”) will NOT be accepted when a house phone is

connected to an entry phone.  The toggle command will be accepted if a house phone goes off-hook
and dials the toggle relay command without calling the entry phone (“

#1

Q

#

” to toggle door strike relay 1

from it’s current position for example). 

G.  Dialing “#” on Cable Company Provided Phone Lines

On some cable company provided phone lines, when the house phones go off-hook and dial “#” as the first digit
of a command to monitor an entry phone or control a door strike relay, the cable company provided line will
produce a short break in the line and this short break will cause the 

C-2000B

to not accept the command. This

problem can be corrected by enabling the “# Conflict Mode” 

(1#67

, see 

Programming

section 

M

). When the “#

Conflict Mode” is enabled and “#” is the first digit dialed by a house phone, the 

C-2000B

immediately switches

the house phone to an artificial line, which allows the monitor or relay control command to work properly. The “#
Conflict Mode” can be disabled by entering “

0#67

” in programming.

Summary of Contents for C-2000B

Page 1: ...65 E 70 and E 75 Phones K 1500 7 Stainless Steel Panel Phone K 1700 3 and K 1705 3 Phone with Keypad K 1900 8 Stainless Steel Panel Phone with Keypad Or use with any analog touch tone phone Provides e...

Page 2: ...Analog Station Mode DIP switch 5 ON DIP Switches see page 9 Power Input 13 8VAC 1 25A adapter included Note The C 2000B is not recommended to be installed in combination with the TR 1 Toll Restrictor...

Page 3: ...Stations E 10A E 60 E 40 K 1700 3 Ring Gen Ring Gen Ring Gen Ring Gen Ring Gen Ring Gen Ring Gen Ring Gen Note Keypads used for keyless entry only Note A C O line is not required but the unit must be...

Page 4: ...Electronic devices are susceptible to lightning and power station electrical surges from both the AC outlet and the telephone line It is recommended that a surge protector be installed to protect agai...

Page 5: ...G CO LINE INPUT GND OUT TO PHONES USB USB TRIG 1 TRIG 2 TRIG 3 TRIG 4 MSG MSG MSG MSG POWER PAGE MUTE AUDIO PAGE LOUD RING IO COM SPK OUTPUT C O Phone Line DIP Switch 1 must be ON DIP Switches 1 and 5...

Page 6: ...OR STRIKE 1 ENTRY PHONE 2 DOOR STRIKE 2 ENTRY PHONE 3 DOOR STRIKE 3 ENTRY PHONE 4 DOOR STRIKE 4 DOORBELL SWITCH AUX INPUT AUX CONTACT OUTPUT PHONE LINE INPUT LINE OUT TO PHONES ANALOG STATION INPUT ST...

Page 7: ...double beep will indicate that you have accessed the programming mode Step 4 You can now touch tone program the features listed in section B Step 5 When finished programming hang up and move DIP switc...

Page 8: ...es factory disabled 4 6 digits 0 9 Q 51 Q 56 Door strike 1 activation time 5 99 seconds factory set to 5 seconds 2 digits 00 99 19 Door strike 2 activation time 5 99 seconds factory set to 5 seconds 2...

Page 9: ...Mode 3 OFF Entry Phone automatic disconnect CPC disabled Note Viking handsfree entry phones require CPC for faster automatic disconnect 3 ON Entry Phone automatic disconnect CPC enabled factory settin...

Page 10: ...ill be called automatically answer see the Product Manual for your entry phone and begin ringing the house phones terminals 4 and 5 LINE OUT TO PHONES The house phones can then be answered door strike...

Page 11: ...eyless codes programmed for an entry phone and not master codes If a master keyless code is entered with Global Keyless Entry enabled the C 2000B will activate the relay for the entry phone the user i...

Page 12: ...D displays may not be compatible with certain characters Entry phone calls are factory set to ring the house phones in a custom double ring cadence 7 seconds on 3 seconds off 7 seconds on then 4 secon...

Page 13: ...cepted when the house phones pick up and is the first digit dialed Entry Phone Caller ID and Call waiting ID 1 Entry Phone 1 2 Entry Phone 2 3 Entry Phone 3 4 Entry Phone 4 C Activating Door Strike Ga...

Page 14: ...e designed for intermittent operation only The latch and toggle commands should NOT be used with these intermittent strikes or damage to the strike may occur Only use the latch and toggle commands wit...

Page 15: ...odes and or manually dialing extensions K 1700 3 K 1705 3 K 1900 8 K 1700 3 BN D10 Directory Any Analog Touch Tone Phone Entry phones with built in auto dialers for phone systems without ringdown capa...

Page 16: ...ECORDABLE TRIGGERED AUDIO CHIMES MESSAGES POWER 13 8 VAC USB LED POWER MUTE AUDIO PAGE PAGE TRIGGER OUTPUT WET 12VDC DRY N C COM N O WAVE FILE INPUT TRIGGERED AUDIO CHIME MESSAGE SELECTIONS PER TRIGGE...

Page 17: ...16 Entry phone 1 one time use keyless entry codes factory disabled 4 6 digits 0 9 Q 11 Q 16 Entry phone 2 keyless entry codes factory disabled 4 6 digits 0 9 21 26 Entry phone 2 one time use keyless e...

Page 18: ...ollowed by 47 If you have forgotten your security code follow the steps in Programming section A 2 Accessing the Programming Mode Locally Security Code Bypass Mode Note The security code must be six d...

Page 19: ...QQ To disable this feature enter 57 without any preceding digits The C 2000B determines which direction the touch tone is coming from and only responds to touch tones from the called phone The factory...

Page 20: ...he auxiliary relay during the monitor once the entry phone answers so a camera or light can be activated while monitoring Auxiliary Contact Programming DIP switch 1 OFF Enter Digits Location Auxiliary...

Page 21: ...aximum Entry Phone Ring Count on page 20 the C 2000B stops ringing that entry phone and remains in the programming mode for up to 20 seconds ready for another C 2000B program command When the entry ph...

Page 22: ...the relay A short buzz will indicate the door strike relay is off In this mode no caller ID data is generated by the controller and no entry phone identifier beeps are provided when the call is answe...

Page 23: ...the door Keyless entry codes also affect the operation of the auxiliary relay contacts if the auxiliary contacts have been programmed to trigger when an entry phone has gone off hook This is when DIP...

Page 24: ...ODUCT SOLD HEREUNDER EXCLUSIVE REMEDY AND LIMITATION OF LIABILITY WHETHER IN AN ACTION BASED ON CONTRACT TORT INCLUDING NEGLIGENCE OR STRICT LIABILITY OR ANY OTHER LEGAL THEORY ANY LIABILITY OF VIKING...

Reviews: