background image

E.  Using the C-2000B with an E-70, E-75, Proximity Card Reader or a Keyless Entry Keypad

The 

C-2000B

can also be used without a C.O. line. This is ideal for connecting the 

C-2000B

to an unused trunk/line

input of your phone system or connecting to phones used only for doorbox communication.

D.  Using a C-2000B without a C.O. Line

LED3

LED1

LED2

LED4

LED5

LED6

LED7

C

C

C

C

C

C

C

J11-

1

2

3

J10-

1

2

3

J9-

1

2

3

J8-

1

2

3

J7-

1

2

3

12

3

on

4

5

VIKING

©

MODEL C-2000B 

VIKING

ELECTRONICS

HUDSON, WI  54016

ADVANCED DOOR/GATE AND

ENTRY PHONE CONTROLLER

1     2     3     4     5     6     7

8 9 1 0 11 12 13

15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32

PWR 13.8 V

A

C

EARTH GND

ENTR

Y

 PHONE 1

DOOR STRIKE 1

ENTR

Y

 PHONE 2

DOOR STRIKE 2

ENTR

Y

 PHONE 3

DOOR STRIKE 3

ENTR

Y

 PHONE 4

DOOR STRIKE 4

DOORBELL

 SWITCH /

AUX. INPUT

AUX. CONT

ACT

OUTPUT

PHONE LINE

INPUT

LINE OUT

T

O

 PHONES

ANALOG ST

A

TION

INPUT

or

Standard

Analog

Phones

Unused Line /

Trunk Input on
Phone System

(PABX/KSU)

13.8V AC

Adapter

(included)

120V AC

DIP Switch 5

must be OFF

(see page  9)

14

d

s

LED3

LED1

LED2

LED4

LED5

LED6

LED7

C

C

C

C

C

C

C

J11-

1

2

3

J10-

1

2

3

J9-

1

2

3

J8-

1

2

3

J7-

1

2

3

12

3

on

4

5

VIKING

©

MODEL C-2000B 

VIKING

ELECTRONICS

HUDSON, WI  54016

ADVANCED DOOR/GATE AND
ENTRY PHONE CONTROLLER

1     2     3     4     5     6     7

8 9 1 0 11 12 13

15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32

PWR 13.8 V

A

C

EARTH GND

ENTR

Y

 PHONE 1

DOOR STRIKE 1

ENTR

Y

 PHONE 2

DOOR STRIKE 2

ENTR

Y

 PHONE 3

DOOR STRIKE 3

ENTR

Y

 PHONE 4

DOOR STRIKE 4

DOORBELL

 SWITCH /

AUX. INPUT

AUX. CONT

ACT

OUTPUT

PHONE LINE

INPUT

LINE OUT

T

O

 PHONES

ANALOG ST

A

TION

INPUT

STAND-ALONE

DOOR CONTROLLER

ENTRY SYSTEM

VIKING

PROGRAM

PHONE

GANG
PROG

COMM

ELECTRONICS

HUDSON, WI 54016

VIKING

©

MODEL ES-1

POWER 12 VDC

BLK

RED

GRN

WHT

ENTRY POINT

WIEGAND

DEVICE

LOG
BUS

Viking PRX-1

Card Reader

(not included,

DOD 221)

Viking PRX-4

Keypad

(not included,

DOD# 199)

|

AND / OR

|

12V DC

Adapter

(included)

120V AC

13.8V AC

Adapter

(included)

120V AC

(Power typically

not required for

gate controllers)

Door Strike/

Magnetic Lock

5A@30VDC/
250VAC maximum

- OR -

Viking E-70-SS

Entry Phone

(not included)

14

Also available, not shown:

Viking PRX-2 Card Reader/Keypad 

(DOD 219)

Viking PRX-3 Card Reader 

(DOD 228)

Step 1.

Connect the power, required entry phones and door strike outputs (if required) as shown in section 

A

.

Step 2.

Connect an analog phone or unused phone system (PABX/  KSU) line /trunk port to terminals 

4

5

,

LINE OUT TO PHONES

” on the 

C-2000B

.

Step 3.

Access programming as shown in 

Programming

section 

A

2.

on page 7.  Enter 

Q

5

, two beeps should

be heard.

Step 4.

Enter additional desired programming, then hang-up the phone and place DIP switch 2 back to the

OFF

position.

Step 1.

Program the 

ES-1

“Relay Activation Time” to match the “Door Strike Activation Time” on the 

C-2000B

.

Step 2.

Connect the 

ES-1

relay output in parallel with the door strike output contacts on the 

C-2000B

.

Step 3.

Connect the entry phones and door strike outputs (if required) as shown in section A.

6

Summary of Contents for C-2000B

Page 1: ...65 E 70 and E 75 Phones K 1500 7 Stainless Steel Panel Phone K 1700 3 and K 1705 3 Phone with Keypad K 1900 8 Stainless Steel Panel Phone with Keypad Or use with any analog touch tone phone Provides e...

Page 2: ...Analog Station Mode DIP switch 5 ON DIP Switches see page 9 Power Input 13 8VAC 1 25A adapter included Note The C 2000B is not recommended to be installed in combination with the TR 1 Toll Restrictor...

Page 3: ...Stations E 10A E 60 E 40 K 1700 3 Ring Gen Ring Gen Ring Gen Ring Gen Ring Gen Ring Gen Ring Gen Ring Gen Note Keypads used for keyless entry only Note A C O line is not required but the unit must be...

Page 4: ...Electronic devices are susceptible to lightning and power station electrical surges from both the AC outlet and the telephone line It is recommended that a surge protector be installed to protect agai...

Page 5: ...G CO LINE INPUT GND OUT TO PHONES USB USB TRIG 1 TRIG 2 TRIG 3 TRIG 4 MSG MSG MSG MSG POWER PAGE MUTE AUDIO PAGE LOUD RING IO COM SPK OUTPUT C O Phone Line DIP Switch 1 must be ON DIP Switches 1 and 5...

Page 6: ...OR STRIKE 1 ENTRY PHONE 2 DOOR STRIKE 2 ENTRY PHONE 3 DOOR STRIKE 3 ENTRY PHONE 4 DOOR STRIKE 4 DOORBELL SWITCH AUX INPUT AUX CONTACT OUTPUT PHONE LINE INPUT LINE OUT TO PHONES ANALOG STATION INPUT ST...

Page 7: ...double beep will indicate that you have accessed the programming mode Step 4 You can now touch tone program the features listed in section B Step 5 When finished programming hang up and move DIP switc...

Page 8: ...es factory disabled 4 6 digits 0 9 Q 51 Q 56 Door strike 1 activation time 5 99 seconds factory set to 5 seconds 2 digits 00 99 19 Door strike 2 activation time 5 99 seconds factory set to 5 seconds 2...

Page 9: ...Mode 3 OFF Entry Phone automatic disconnect CPC disabled Note Viking handsfree entry phones require CPC for faster automatic disconnect 3 ON Entry Phone automatic disconnect CPC enabled factory settin...

Page 10: ...ill be called automatically answer see the Product Manual for your entry phone and begin ringing the house phones terminals 4 and 5 LINE OUT TO PHONES The house phones can then be answered door strike...

Page 11: ...eyless codes programmed for an entry phone and not master codes If a master keyless code is entered with Global Keyless Entry enabled the C 2000B will activate the relay for the entry phone the user i...

Page 12: ...D displays may not be compatible with certain characters Entry phone calls are factory set to ring the house phones in a custom double ring cadence 7 seconds on 3 seconds off 7 seconds on then 4 secon...

Page 13: ...cepted when the house phones pick up and is the first digit dialed Entry Phone Caller ID and Call waiting ID 1 Entry Phone 1 2 Entry Phone 2 3 Entry Phone 3 4 Entry Phone 4 C Activating Door Strike Ga...

Page 14: ...e designed for intermittent operation only The latch and toggle commands should NOT be used with these intermittent strikes or damage to the strike may occur Only use the latch and toggle commands wit...

Page 15: ...odes and or manually dialing extensions K 1700 3 K 1705 3 K 1900 8 K 1700 3 BN D10 Directory Any Analog Touch Tone Phone Entry phones with built in auto dialers for phone systems without ringdown capa...

Page 16: ...ECORDABLE TRIGGERED AUDIO CHIMES MESSAGES POWER 13 8 VAC USB LED POWER MUTE AUDIO PAGE PAGE TRIGGER OUTPUT WET 12VDC DRY N C COM N O WAVE FILE INPUT TRIGGERED AUDIO CHIME MESSAGE SELECTIONS PER TRIGGE...

Page 17: ...16 Entry phone 1 one time use keyless entry codes factory disabled 4 6 digits 0 9 Q 11 Q 16 Entry phone 2 keyless entry codes factory disabled 4 6 digits 0 9 21 26 Entry phone 2 one time use keyless e...

Page 18: ...ollowed by 47 If you have forgotten your security code follow the steps in Programming section A 2 Accessing the Programming Mode Locally Security Code Bypass Mode Note The security code must be six d...

Page 19: ...QQ To disable this feature enter 57 without any preceding digits The C 2000B determines which direction the touch tone is coming from and only responds to touch tones from the called phone The factory...

Page 20: ...he auxiliary relay during the monitor once the entry phone answers so a camera or light can be activated while monitoring Auxiliary Contact Programming DIP switch 1 OFF Enter Digits Location Auxiliary...

Page 21: ...aximum Entry Phone Ring Count on page 20 the C 2000B stops ringing that entry phone and remains in the programming mode for up to 20 seconds ready for another C 2000B program command When the entry ph...

Page 22: ...the relay A short buzz will indicate the door strike relay is off In this mode no caller ID data is generated by the controller and no entry phone identifier beeps are provided when the call is answe...

Page 23: ...the door Keyless entry codes also affect the operation of the auxiliary relay contacts if the auxiliary contacts have been programmed to trigger when an entry phone has gone off hook This is when DIP...

Page 24: ...ODUCT SOLD HEREUNDER EXCLUSIVE REMEDY AND LIMITATION OF LIABILITY WHETHER IN AN ACTION BASED ON CONTRACT TORT INCLUDING NEGLIGENCE OR STRICT LIABILITY OR ANY OTHER LEGAL THEORY ANY LIABILITY OF VIKING...

Reviews: