background image

Dimensions

7

Dimensions

6

Gas 36” and 48” W. Ranges

35-7/8”

(91.1 cm)

35-7/8”

(91.1 cm) min.

to

37”

(94 cm) max.

1-3/16” 

(3 cm

)*

Note: 

Unit shown with standard island trim.

Note: 

All ranges installed with a backguard against a combustible wall require a standoff with

the backguard which will add 3/8” (.9 cm) to the overall range depth.

35-7/8”

(91.1 cm) min.

to

37”

(94 cm) max.

19-7/16”

(49.4 cm)

47-5/8”

(121.0 cm)

28”

(71.1 cm)

25-11/16”

(65.3 cm)

7-15/16”

(20.2 cm)

29-1/16”

 

(73.8 cm)

2-13/16”

 (7.1 cm)

1-3/16”

 (3 cm)

31-3/8”

 

(79.7 cm)

Gas 36” and 48” W. Ranges

Note: 

Unit shown with standard island trim.

47-7/8”

(121.6 cm)

35-7/8”

(91.1 cm) min.

to

37”

(94 cm) max.

1-3/16” 

(3 cm

)*

Summary of Contents for BVGRC836-6B-S

Page 1: ...Gas Range INSTALLATION GUIDE Viking Range Corporation 111 Front Street Greenwood Mississippi 38930 USA 662 455 1200 For product information call 1 888 VIKING1 845 4641 or visit vikingrange com F21033...

Page 2: ...n minor personal injury or property damage All safety messages will identify the hazard tell you how to reduce the chance of injury and tell you what can happen if the instructions are not followed WA...

Page 3: ...can cause serious injury or death and which are known to the state of California to cause cancer birth defects or other reproductive harm To reduce the risk from substances in the fuel or from fuel c...

Page 4: ...a combustible wall require a standoff with the backguard which will add 3 8 9 cm to the overall range depth 35 7 8 91 1 cm min to 37 94 cm max 19 7 16 49 4 cm 47 5 8 121 0 cm 28 71 1 cm 25 11 16 65 3...

Page 5: ...bottom of cabinets Specifications 8 Minimum clearances from adjacent combustible construction Below cooking surface 36 91 4 cm and below Sides 0 Top grate support 36 91 4 cm Above cooking surface abov...

Page 6: ...egulator used on this range can withstand a maximum input pressure of 1 2 PSI 14 0 W C P If the line pressure is in excess of that amount a step down regulator will be required The appliance must be d...

Page 7: ...dues and any dust or debris before being used then rinsed and wiped dry Solutions stronger than soap and water are rarely needed 12 Electrical Gas Requirements 28 3 4 72 8 cm Gas connection Gas access...

Page 8: ...lift the oven Remove door before installation to ensure that it is not used to lift the unit DO NOT lift or carry the door by the handle Removing the door must be done by your dealer a qualified lice...

Page 9: ...d properly to prevent product from tipping over 7 Set the high corner of range so that the top of side trim is 3 8 0 95 cm above countertop Level range to high corner Anti tip Device Installation 16 1...

Page 10: ...ed against a NON COMBUSTIBLE wall DANGER FIRE HAZARD Backguards come standard with standoff spacers which provide a barrier between back of range and rear wall These must be in place for adequate vent...

Page 11: ...liquid cleaner designed for this material If buildup occurs DO NOT use steel wool abrasive cloths cleansers or powders If it is necessary to scrape stainless steel to remove encrusted materials soak w...

Page 12: ...________________________________________________ _______________________________________________________________________________________________________________________________________________________...