A.  Connect / Disconnect

Open the “Viking IP Programming” software on the PC and the start screen shown below will appear.  Any Viking IP speakers that 
are connected to the network will appear on the list.  Simply select the 

300TB-IP

 on the list and click on the “Connect” button at the 

bottom or double click the selected speaker. If no username and password have been programmed and the security code of the 
selected unit is still set to default (845464), the PC software will not require entering a username, password or security code to 
connect to the 

300TB-IP

. If the 

300TB-IP

 has been programmed with a username and password, a pop up window will ask for the 

username followed by the password. If the unit’s security code has been changed from “845464”, it will then prompt for the correct 
security code. 

300TB-IP

’s have a default name of “VIKING_MK64_Vik02”, so if many 

300TB-IP

’s are connected to the same network 

and all have the default name, MAC addresses must be used to identify each 

300TB-IP

When finished programming, click the “Disconnect” button at the bottom. Closing the program will also automatically disconnect the unit.

 

B.  Configuring the 300TB-IP Network Settings

Step 1.

Open the “Viking IP Programming” software on a windows PC that is connected to the same LAN as the 

300TB-IP

 speaker to be 

programmed.

Step 2.

The window in the upper left corner of the menu will show you each 

300TB-IP

 speaker that is connected to that LAN. Select the unit 

with the same MAC address shown on the label located next to the Ethernet connector on the 

300TB-IP

 speaker.

Step 3.

Click on the “connect” button. A default 

300TB-IP

 has no username or password programmed, the security code is set to “845464” and 

when configured this way, you are instantly connected to the 

300TB-IP

. If the 

300TB-IP

 has been programmed with a username and 

password, a pop up window will ask for the username followed by the password. If the unit’s security code has been changed from 
“845464”, it will then prompt for the correct security code, then click “retry”.

Step 4.

The program will then read and display the 

300TB-IP

 speaker’s IP and programming settings.

Step 5.

Click on the “IP Settings” tab.

Step 6.

Select the appropriate value Static IP Settings or DHCP for “Set Unit IP Address via”. 

 

Note:

 Changing the IP address will cause you to 

have to reconnect to the unit.  Enter the values for the fields in “if DHCP fails” or “Static IP Settings” as needed.

Step 7.

Set the “Unit Name”, “Logging / Time Server Settings” as needed.

Step 8.

Select Peer-Peer in the “SIP Server / Peer to Peer Settings” to use the unit in Peer to Peer mode or for Multicast paging only.  Select 
Server to register with a SIP registrar server and fill in the “Outbnd Proxy” (SIP Outbound Proxy Server Address, “ip:port”), “Authentic. ID” 
(SIP Authentication ID), “Username” (SIP Username, <string>), “Password” (SIP Password), and “Caller ID” (SIP Caller ID) with values 
from your VoIP provider. Required fields will be red when the unit is not registered.

Summary of Contents for 300TB-IP

Page 1: ...A Maximum Output Level 113 dB SPL 1M Amplifier 6 Watt class D Connections 1 RJ45 10 100 Base T 2 butt connectors The 300TB IP Paging Horn with Talk Back can be used for standard one way SIP endpoint p...

Page 2: ...to www vikingelectronics com and enter 944 in the search box 2 Click Application Note DOD 944 to open and download the PDF Scan the QR code below to open and download the Viking VoIP SIP System Compat...

Page 3: ...otocol is an Internet protocol standard that specifies a way for programs to manage the real time transmission of multimedia data over either unicast or multicast network services Server A computer or...

Page 4: ...o the correct IP address Back View PoE LAN Port 10 100 PoE Class 3 13 Watts Connect to your LAN via RJ45 plug and CAT5 or greater twisted pair wire Red Call Status LED Flashes when unit is not registe...

Page 5: ...ng nuts loose rotate and angle the horn into position then tighten both wing nuts to secure Round Mounting Plate Base Screws not included 4 0 217 diameter 1 99 3 26 1 99 Mounting Plate Dimensions SIP...

Page 6: ...1 Gbps network speed for other equipment on network Available LAN with PoE class 3 13 Watts Ethernet cable CAT5 minimum 1 MB minimum free hard drive space for installation 16MB of free physical RAM Do...

Page 7: ...show you each 300TB IP speaker that is connected to that LAN Select the unit with the same MAC address shown on the label located next to the Ethernet connector on the 300TB IP speaker Step 3 Click o...

Page 8: ...cting an integer 1 to PSA 94 in ID for all packets Step 4 Set the Priority Code Point PCP value for all not SIP and RTP packets in the PCP for all packets input 0 is default priorities are from low to...

Page 9: ...ash slowly for 3 seconds 2 beeps flash fast for 6 seconds 4 beeps then light steady indicating when to remove the short across the Trig In wires Step 4 You can now enter programming by following the s...

Page 10: ...8 Redial on Ring No Answer Disabled or 1 9 rings factory set to 7 37 18 Redial on Busy Disabled or Enabled factory set to Enabled 38 18 Mute Current Next Alarm 39 19 Permanent Alarm Mute 40 19 Program...

Page 11: ...ctory Setting Enabled When registered to a SIP server in the event that registration is lost you can program the unit to re resolve using the current SIP server IP address or route pages through an al...

Page 12: ...SIP emergency calls have the highest priority and Polycom Group 25 multicast has the second highest priority The priority options allow you to determine the priorities for Polycom Groups 1 through 24...

Page 13: ...oups can also be used for up to ten different paging zones for receiving audio streams A paging zone can consist of one or many 300TB IP multicast speakers There is no limit to how many speakers can b...

Page 14: ...on the Alarm Firmware tab Factory Setting 845464 NOTE The security code must be 6 digits and cannot include a Q or 14 Security Code The Access Code is primarily used along with the Auto Answer Secure...

Page 15: ...on time on any outbound call from the speaker phone This mode is useful for activating a door chime etc When activating door chimes a 0 5 1 second relay activation time is recommended Ring Mode When p...

Page 16: ...tablished by entering touch tone command 9 The speaker will remain on for the duration of the call ON In the ON mode the speaker is enabled during In bound and Out bound calls OFF Until Answered In th...

Page 17: ...og audio for ringback or busy detection Factory Setting Enabled 31 In Band Audio Call Progress The In Band Audio Detection level Sensitivity can be set from 1 to 9 1 minimum setting 9 highest setting...

Page 18: ...ming call but will output a loud ring signal out of the speaker in a 2 seconds ON 4 seconds OFF ring pattern The speaker will automatically increase or decrease the ring volume based on background amb...

Page 19: ...ing the data back into the speaker 42 IP Firmware Update IP is currently not available The ability to update IP firmware will be made available in a later release of Viking IP Programming software If...

Page 20: ...ramming or for importing programming when installing multiple units with a majority of the same programming Clicking on the Clear Speaker Settings button in programming will reset all of the Programmi...

Page 21: ...the volume of the loud ring based on the background noise around the unit If Night Ring Timed Operation is enabled and an inbound SIP call is received between the programmed start and stop times and t...

Page 22: ...300TB IP or on an inbound SIP call to the unit when the Inbound Call Mode is set to auto answer After the unit auto answers the call one beep will be heard if Pre Page Alert Tone is enabled If the Acc...

Page 23: ...ts 5A 30VDC 250VAC max Connect to Doorstrike Mag Lock Gate Controller etc 2 Gel Filled Butt Connectors included Doorstrike Magnetic Lock 120V AC Door near Speaker 4 1 IN1 C IN2 IN3 C IN4 2 3 4 5 6 Rel...

Page 24: ...onal analog speakers The LED on the 40 IP can be programmed to light during paging For more info see DOD 503 40 IP IP Speaker for SIP Endpoint Paging SIP Multicast Paging Adapter The Viking model 40TB...

Page 25: ...PA 250 IP SIP Multicast Paging Amplifier provides up to 250 Watts of loud paging for SIP based VoIP phone systems hardware or hosted cloud based service provider The PA 250 IP can be used for standard...

Page 26: ...EACH PROVISION IS A SEPARABLE AND INDEPENDENT ELEMENT OF RISK ALLOCATION AND IS INTENDED TO BE ENFORCED AS SUCH If trouble is experienced with the 300TB IP Speaker for repair or warranty information...