22
D. Operation Commands (Relay Mode must be set to “Door Strike”)
Feature
Tone Tone
Command
Description
Activate
Ext Relay
or
___ ___
Momentarily activate ext relay (1 or 2 digits, factory set to
).
Un-Latch
Ext Relay
Q
0
Un-latch* (deactivate) the ext relay.
Latch
Ext Relay
Q
1
Latch* (continuously activate) the ext relay.
Disconnect
#
Disconnects or forces the speaker to hang up.
Send ID
Q
Send I.D. number (if programmed).
* NOTE:
Latching commands must be enabled in programming.
The following commands can be entered after answering an outbound SIP call from the
300TB-IP
or on an inbound
SIP call to the unit, when the Inbound Call Mode is set to auto answer. After the unit auto answers the call, one beep
will be heard if Pre Page Alert Tone is enabled. If the Access Code has been disabled, you can now enter the Operation
Commands listed below. If an Access Code has been programmed, enter the Access Code digits. Once the correct
code has been entered, two beeps will be heard and you can now enter the Operation Commands listed below.
Troubleshooting
If the unit cannot register with the programmed SIP server, the “Status” LED will blink on and off every two seconds until
communication is restored. This alerts a potential user of a problem with the device that will prevent an emergency phone
call from being made.