9
Step 1.
Power down the
300TB-IP
speaker by disconnecting the LAN
Cable (RJ45 plug).
Step 2.
Provide a short across the “Trig In” wires, then reconnect the LAN
Cable (RJ45 plug).
Step 3.
Keep the short across the “Trig In” wires until you hear a single beep, silence and then 2 beeps (approximately 11 seconds). Then
remove the short across the “Trig In” wires. The Status LED will remain off for 5 seconds, light steady for 3 seconds, flash slowly for 3
seconds then fast flash, (after the 2 beeps), indicating when to remove the short across the “Trig In” wires.
Step 4.
The security code is now reset to
845464
(factory default).
Step 5.
You can now enter programming by following the steps in section
A
.
D. Manually Resetting the Security Code to Enter Programming
E. Manually Resetting All Network Parameters to Factory Default
Step 1.
Power down the
300TB-IP
speaker by disconnecting the LAN
Cable (RJ45 plug).
Step 2.
Provide a short across the “Trig In” wires, then reconnect the LAN
Cable (RJ45 plug).
Step 3.
Keep the short across the “Trig In” wires until you hear a single beep, silence and then 2 beeps (approximately 11 seconds). Continue
with the short across the “Trig In” wires until you hear 4 more beeps (approximately 6 seconds later), then remove the short across the
“Trig In” wires. The Status LED will remain off for 5 seconds, light steady for 3 seconds, flash slowly for 3 seconds (2 beeps) flash fast
for 6 seconds, (4 beeps), then light steady indicating when to remove the short across the “Trig In” wires.
Step 4.
You can now enter programming by following the steps in section
A
.
Programming Features
Index
DESCRIPTION
Section
Page
Connect / Disconnect
A
7
VLAN Settings
C
8
Unit Name
1
10
SIP Server
2
10
Peer to Peer Settings
3
10
Outbound Proxy
4
11
Authentication ID
5
11
Register Fails (Re-Resolve or Alternate Server)
6
11
Pre Page Tone
7
11
Multicast Page Type
8
11
Multicast Page Time Out (1 - 255 seconds, factory set to 180 seconds)
9
11
SIP Page / Call Priority VS Multicast
10
12
Multicast Paging (Standard or Polycom, factory set to Standard)
11
13
Multicast Paging Volume (0 - 1 9, factory set to 1)
12
13
Emergency Phone Number and Non-Emergency Phone Number
13
14
Security Code (factory set to 845464)
14
14
ID Number
15
14
Access Code (1 - 6 digits, blank = Disabled, factory set to 123456)
16
14
Night Ring Timed Operation
17
14
Time Zone Settings / Daylight Saving Time
18
14
External Relay (factory set to Disabled)
19
15
Ext Relay Mode
(Door Strike, Outbound Call, Phone or Paging, Doorbell, Ring, Ring Flash, factory set to Door Strike)
20
15
Ext Relay Activation Command (1 or 2 digits, factory set to
)
NOTE:
Relay Mode must be set to Door Strike.
21
15
Note:
This procedure will not erase a username and password used to access the
300TB-IP
program mode. Only the security code is set to default.
Note:
This procedure will erase a username and password that are used to access the
300TB-IP
program mode.