21
Optional Secure Remote Relay Control Using a Viking Model RC-4A
Switch
SIP VoIP PBX,
SIP Cloud
Based Service
Provider
|
OR
|
PC with
SIP Server
Software
Internet
PoE
Switch
12V DC Adapter
(included)
Sensor
Examples:
Door Sensor
Gate Sensor
Door Sensor
Door Sensor
N.O.
COM.
Connect to Doorstrike,
Mag Lock, Gate Controller, etc.
2 Gel-Filled Butt
Connectors
(included)
Doorstrike /
Magnetic Lock
120V AC
Door / Gate Examples
Door near Speaker 1
N.O.
COM.
2 Gel-Filled Butt
Connectors
(included)
(Power typically not
required for gate controllers)
Gate Controller
300-IP
Relay 2 Output Contacts
(5A@30VDC / 250VAC max)
Connect to Gate Controller, etc.
Gate near Speaker 2
N.O.
COM.
2 Gel-Filled Butt
Connectors
(included)
Doorstrike /
Magnetic Lock
120V AC
Door near Speaker 3
N.O.
COM.
Relay 4 Output Contacts
(5A@30VDC /
250VAC max)
Connect to Doorstrike,
Mag Lock, Gate Controller, etc.
2 Gel-Filled Butt
Connectors
(included)
Doorstrike /
Magnetic Lock
120V AC
Door near Speaker 4
1
IN1 C IN2 IN3 C IN4
2 3 4 5 6
Relay 1 Output Contacts
(5A@30VDC / 250VAC max)
Connect to Doorstrike,
Mag Lock, Gate Controller, etc.
Relay 3 Output Contacts
(5A@30VDC / 250VAC max)
300-IP
300-IP
300-IP
For applications requiring remote relay control for up to 4 relays, a Viking model
RC-4A
Remote Relay Controller
can be used. The relay controller is mounted securely inside the building and connected to the same LAN as the
300-IP
. The
300-IP
will send an encrypted message to the
RC-4A
to activate its relays which control the door
strikes / gates.
Up to four
300-IP’s
can communicate with one
RC-4A
allowing you to securely control four entrances.
When using an
RC-4A
for remote relay control the
300-IP
should be set to “Ext 1,2,3,4” (see Programming section
19).
For more information on the
RC-4A
, see DOD 582.