background image

10

Programming Features

 

Index

                DESCRIPTION       

Section

Page

SIP Paging Volume (0 - 1   9, factory set to 1)

22

16

Ring Volume (0 - 19, factory set to 5)

23

16

SIP Page Length Time Out (Disabled or 1 - 9 minutes, factory set to 3 minutes)

24

16

Multicast Page Length Time Out (1 - 255 seconds, factory set to 180 seconds)

25

16

Inbound Call Mode 

(Disabled, Auto Answer, Auto Answer-Secure, Ring, factory set to Auto Answer)

26

16

Ring Cadence (factory set to Normal Ring = 2 seconds ON, 4 seconds OFF)

27

17

Mute Current / Next Alarm

28

17

Permanent Alarm Mute

29

17

Programming Username and Password

30

17

IP Firmware

31

18

Unit Firmware

32

18

Import / Export

33

18

Clear Speaker Settings

34

18

   Clear IP Settings

35

18

Diagnostics (used to check External relay operation)  

36

18

3.  Peer to Peer Settings

2.  SIP Server

When set to Peer to Peer mode, a SIP server is not used. The unit should be programmed with a static IP address and 
username, a password is not used. Caller ID can be programmed if needed. Simply call the unit by entering the 
programmed “[email protected]...(static IP address for the unit)”. The static IP address is normally programmed into 
a page button on the VoIP telephones. 

NOTE:

Peer to Peer mode does not affect multicast paging.

1.  Unit Name

Up to a 30 character unit name can be assigned to the 

300-IP

 being programmed. 

Programming Features

Enter the IP address or URL of your SIP server or service provider in this field. The SIP server IP address is limited to 
74 characters.  

Note: 

If an alternate SIP server IP address is programmed, the IP address for the SIP server and 

alternate SIP server will be limited to 31 characters. 

Note: 

If outbound proxy is not required, enter the SIP server IP 

address into the Outbnd Proxy field.

4.  Outbound Proxy 

If your SIP provider requires an outbound proxy IP address enter it in the “Outbnd Proxy” field. If outbound proxy is not 
required enter the SIP sever IP address into the “Outbnd Proxy” field.

 

NOTE: 

If not required, this field must match your 

SIP server IP address.

5.  Authentication ID

If your SIP provider requires Authentication ID, enter it in the “Authentic. ID” field.

 

If Authentication ID is not required, 

leave this field blank.

6.  Register Fails (Re-Resolve or Alternate Server)

When registered to a SIP server in the event that registration is lost you can program the unit to re-resolve using the 
current SIP server IP address or route pages through an alternate SIP server. With Alternate Server selected enter the 
IP address of the alternate SIP server in the field next to the Register Fails drop down box.  

Note: 

With an alternate  

SIP server IP address programmed, the IP address for the SIP server and alternate SIP server will be limited to 31 
characters.

Summary of Contents for 300-IP

Page 1: ...pliance IEEE 802 3 af PoE SIP 2 0 RFC3261 100BASE TX with auto cross over Regulatory Compliance CE FCC Part 15 and Canada ICES 003 Class A Maximum Output Level 113 dB SPL 1M Amplifier 6 Watt class D C...

Page 2: ...to www vikingelectronics com and enter 944 in the search box 2 Click Application Note DOD 944 to open and download the PDF Scan the QR code below to open and download the Viking VoIP SIP System Compat...

Page 3: ...tocol is an Internet protocol standard that specifies a way for programs to manage the real time transmission of multimedia data over either unicast or multicast network services Server A computer or...

Page 4: ...he correct IP address Back View PoE LAN Port 10 100 PoE Class 3 13 Watts Connect to your LAN via RJ45 plug and CAT5 or greater twisted pair wire Red Call Status LED Flashes when unit is not registered...

Page 5: ...tep 4 With both wing nuts loose rotate and angle the horn into position then tighten both wing nuts to secure Round Mounting Plate Base Screws not included 4 0 217 diameter 1 99 3 26 1 99 Mounting Pla...

Page 6: ...ps 1 Gbps network speed for other equipment on network Available LAN with PoE class 3 13 Watts Ethernet cable CAT5 minimum 1 MB minimum free hard drive space for installation 16MB of free physical RAM...

Page 7: ...how you each 300 IP speaker that is connected to that LAN Select the unit with the same MAC address shown on the label located next to the Ethernet connector on the 300 IP speaker Step 3 Click on the...

Page 8: ...ecting an integer 1 to PSA 94 in ID for all packets Step 4 Set the Priority Code Point PCP value for all not SIP and RTP packets in the PCP for all packets input 0 is default priorities are from low t...

Page 9: ...t for 6 seconds 4 beeps then light steady indicating when to remove the short across the Reset wires Step 4 You can now enter programming by following the steps in section A Programming Features Index...

Page 10: ...unit name can be assigned to the 300 IP being programmed Programming Features Enter the IP address or URL of your SIP server or service provider in this field The SIP server IP address is limited to...

Page 11: ...tory Setting Standard shown above 9 Pre Page Tone When enabled a short beep will be heard prior to SIP or Multicast paging audio The volume of the Pre Page Alert Tone will match the volume setting of...

Page 12: ...SIP Page Priority Level can be set to Polycom or None See the following tables for the order of priorities with each setting As shown Polycom Group 25 multicast is the highest priority The priority o...

Page 13: ...s no limit to how many speakers can be in a given paging zone Each multicast group is defined by a multicast address and port number Each multicast group is assigned a priority allowing simultaneously...

Page 14: ...alls are handled NOTE For timed Night Ringing the unit must be synced with a time server If the Night Ringing feature is enabled in the software you will be asked to use Viking Time Server when change...

Page 15: ...Viking model SL 2 strobe light etc Ring Flash Mode When programmed for Ring Flash Mode the relay will momentarily turn on and off in a 400 ms on off cadence while the ringing extension is called This...

Page 16: ...dles incoming SIP calls One option is to generate a loud ring sound through the speaker The 300 IP can also auto answer a SIP call to transmit a page or control the relay The secure options for auto a...

Page 17: ...ent cadences Factory Setting Normal Ring Normal Ring single ring 2 seconds ON 4 seconds OFF Double Ring double ring 1 second ON 0 5 second OFF 1 second ON 3 5 seconds OFF Short Short Long triple ring...

Page 18: ...Clear Speaker Settings button in programming will reset all of the Programming Features back to their factory default settings NOTE This command will not change or reset your IP settings 34 Clear Spe...

Page 19: ...Type to Polycom Standard Multicast Paging Factory Setting Up to 10 multicast paging groups can be programmed into each unit and each group is assigned a priority level allowing simultaneous arriving m...

Page 20: ...IP call when the Inbound Call Mode is set to auto answer After the unit auto answers the call one beep will be heard if Pre Page Alert Tone is enabled If the Access Code has been disabled you can now...

Page 21: ...Contacts 5A 30VDC 250VAC max Connect to Doorstrike Mag Lock Gate Controller etc 2 Gel Filled Butt Connectors included Doorstrike Magnetic Lock 120V AC Door near Speaker 4 1 IN1 C IN2 IN3 C IN4 2 3 4 5...

Page 22: ...onal analog speakers The LED on the 40 IP can be programmed to light during paging For more info see DOD 503 40 IP IP Speaker for SIP Endpoint Paging SIP Multicast Paging Adapter The Viking model 40TB...

Page 23: ...PA 250 IP SIP Multicast Paging Amplifier provides up to 250 Watts of loud paging for SIP based VoIP phone systems hardware or hosted cloud based service provider The PA 250 IP can be used for standard...

Page 24: ...for diagnosis 2 If the Technical Support Product Specialist determines that the equipment is defective based on the customer s input and troubleshooting a Return Authorization RA number will be issue...

Reviews: