Initial Settings
NOTE:
Installing a shunt, or jumper, on the pins will activate the feature.
CONTROL BOARD SETUP
“Sync”
Used only in conjunction with
Barrier Arm Operators. Activating
this feature allows for synchronized
operation with Barrier Arm Operators.
See page 35.
“Pre-Warning”
Initiates two options for an
audio or visual warning 3 seconds prior to
gate motion and will continue:
1. Until gate reaches closed limit:
“Magnetic Lock” terminals provide a
contact between “COM” and “N.O.”.
2. While gate is moving:
“AUX. PWR” terminals provide 24VDC.
“EXT”
Available for future developments.
“Last Open” - Power Failure Option
Opens the gate automatically when the
battery backup voltage is critically low.
“Auto Open” - Power Failure Option
Opens the gate automatically during
power failure. Resumes normal operation
when power is restored.
!
Disabled when “Solar Mode” is ON.