VIKING TECHNICAL SUPPORT 1.800.908.0884
2 2
Motor Cable - Primary (Single)
NOTE:
The Single Electronic Control Unit is equipped to operate a single gate motor only,
and does not include a Secondary Module. The steps described on page 23 do not apply
for this type of application.
STEP 3
Primary Motor:
a. Connect the BROWN and BLUE
wires from the motor cable to
the Motor Connector at the
Primary Control Board.
!
Tip:
The jumper wire between
terminals 3 & 4 will inform the
control board that an I770
operator is connected.
b. Attach the grounding wire, non
insulated, to the Board Mounting
Plate using the screw provided.
!
I-770
Primary Motor
BROWN
BLUE
JUMPER
JUMPER
NOT USED
NOT USED
NOT USED
ELECTRICAL INSTALLATION
3b
STEP 4
Primary Open Left or Open Right:
Place the terminal block in the proper location for the gate opening direction.
• “OPEN RIGHT” Connector if the gate opens
Inside to the Right
or
Outside to the Left
.
• “OPEN LEFT” Connector if the gate opens
Inside to the Left
or
Outside to the Right
.
3a