Coding in the delivered condition
Possible change
b0:0
With remote control:
Heating mode/reduced
mode: weather-com-
pensated (change cod-
ing only for the heating
circuit M2 with mixer)
b0:1
Heating mode: weather-
compensated
Reduced mode: with
room temperature hook-
up
b0:2
Heating mode: with room
temperature hook-up
Reduced mode: weather-
compensated
b0:3
Heating mode/reduced
mode: with room tem-
perature hook-up
b2:8
Heating with room tem-
perature hook-up must
be programmed for re-
mote control and for the
heating circuit: Room
influence factor 8
(change coding only for
the heating circuit M2
with mixer)
b2:0
Without room influence
b2:1
to
b2:64
Room influence factor
adjustable from 1 to 64
b5:0
With remote control: No
room temperature-de-
pendent heating circuit
pump logic function
(change the coding only
for the heating circuit
with mixer M2)
b5:1
to
b5:8
Heating circuit pump
logic function, see the fol-
lowing table:
Parameter ad-
dress b5: ...
With heating circuit pump logic function: Heating cir-
cuit pump OFF, if
1:
enabled RT
actual
> RT
set
+ 5 K; disabled RT
actual
< RT
set
+ 4 K
2:
enabled RT
actual
> RT
set
+ 4 K; disabled RT
actual
< RT
set
+ 3 K
3:
enabled RT
actual
> RT
set
+ 3 K; disabled RT
actual
< RT
set
+ 2 K
4:
enabled RT
actual
> RT
set
+ 2 K; disabled RT
actual
< RT
set
+ 1 K
5:
enabled RT
actual
> RT
set
+ 1 K; disabled RT
actual
< RT
set
6:
enabled RT
actual
> RT
set
; disabled RT
actual
< RT
set
- 1 K
Code 2
(cont.)
57
Coding
5692
779
GB
Summary of Contents for VITOLADENS333-F
Page 101: ...Parts lists cont 101 Parts lists 5692 779 GB...
Page 102: ...Parts lists cont 102 Parts lists 5692 779 GB...
Page 103: ...Parts lists cont 103 Parts lists 5692 779 GB...
Page 104: ...Parts lists cont 104 Parts lists 5692 779 GB...
Page 105: ...Parts lists cont 105 Parts lists 5692 779 GB...