A
Flue gas test port
Rated output
kW
12.9/19.3
16.1/23.5
Burner stage 2
1
2
1
2
Rated output
kW
12.9
19.3
16.1
23.5
Oil burner nozzle
Type
80°H LE V
80°H LE V
Make: Danfoss
Gph
0.40
0.50
Oil pressure approx.
*
1
bar
8.0-10.5
14.0-17.5
9.0-13.5
16.0-18.5
Max. permissible va-
cuum
in oil line
bar
0.35
0.35
0.35
0.35
Oil throughput
kg/h
1.05
1.58
1.53
1.92
approx.
l/h
1.24
1.86
1.80
2.26
Static burner pres-
sure approx.
mbar
8.0-10.5
15.5-19.5
11.0-15.5
17.5-21.0
CO
2
content approx.
&
Test value w/o cap
%
12.2-13.4
12.2-13.2
&
Test value with cap
%
12.7-13.9
12.7-13.7
Nozzle gap "a"
mm
3.0
+0.2/-0.3
1.5
+0.2/-0.3
(see page 20)
Further details regarding the individual steps
(cont.)
15
Commissioning, inspection, maintenance
5692
779
GB
*1
Due to nozzle tolerances and varying oil characteristics, the oil pressure may vary from
the values shown.