Rated voltage
230 V
Rated frequency
50 Hz
Rated current
6 A
Protection class
I
Protection
IP X 4 D to
EN 60529
Permissible ambient temperature
&
during operation
0 to +40 °C
&
during storage
and transport
-20 to +65 °C
Electronic tempera-
ture limiter setting
82 °C
Temperature limiter
setting
100 °C (fixed)
Line fuse (mains)
max. 16 A
–
Power consumption
160 W
Gas fired boilers
Rated output range
T
V
/T
R
50/30 °C
kW
3.8 to 13
3.8 to 19
5.2 to 26
Rated thermal load
range
for central heating
kW
3.6 to 12.3
3.6 to 17.9
4.9 to 24.7
for DHW heating
kW
3.6 to 16.7
3.6 to 17.9
4.9 to 24.7
Connection values
in relation to the max.
load
Natural gas E
m
3
/h
1.77
1.89
2.61
Natural gas LL
m
3
/h
2.05
2.20
3.04
LPG
kg/h
1.31
1.40
1.93
Product ID
_
-0085 BR 0433
Note
The supply values are only for documentation purposes (e.g. in the gas contract
application) or to estimate the supplementary volumetric settings. Because of
factory settings, the gas pressure must not be altered from these settings.
Reference: 15 °C, 1013 mbar.
Specification
130
Specification
56
92
682
GB
Summary of Contents for Vitodens 333-F
Page 5: ...Keyword index 133 Index cont 5 Index 5692 682 GB ...
Page 123: ...Parts lists cont 123 Parts lists 5692 682 GB ...
Page 124: ...Parts lists cont 124 Parts lists 5692 682 GB ...
Page 125: ...Parts lists cont 125 Parts lists 5692 682 GB ...
Page 126: ...Parts lists cont 126 Parts lists 5692 682 GB ...
Page 127: ...Parts lists cont 127 Parts lists 5692 682 GB ...
Page 128: ...Parts lists cont 128 Parts lists 5692 682 GB ...
Page 135: ...Keyword index cont 135 Keyword index 5692 682 GB ...