38
Calling up code 1
Note
■ On weather-compensated control
units, codes are displayed as plain
text.
■ Codes that are irrelevant due to the
system equipment level or the setting
of other codes will not be displayed.
■ Heating systems with one heating cir-
cuit without mixer and one heating cir-
cuit with mixer:
Initially, the possible coding addresses
"A0" to "d4" for the heating circuit with-
out mixer A1 are scanned
;
then the
coding addresses for the heating cir-
cuit with mixer M2 are scanned.
Press the following keys:
1.
K
+
L
simultaneously for approx. 2
s.
2.
a
/
b
for the required coding
address
;
the address
flashes.
3.
d
to confirm.
4.
a
/
b
for the selected value.
5.
d
to confirm
;
the display
briefly shows "
accepted
"
(weather-compensated
control unit)
;
the address
flashes again.
6.
a
/
b
for the selection of further
addresses.
7.
K
+
L
press simultaneously for
approx. 1 s
;
code 1 is termi-
nated.
Codes
Code 1
5692 760 GB