3.7   Removing transportation securing plates

 

 

The magnetic gasket seal on the door is protected from

 

  mechanical damage by means of the securing plates (M).

 

  Prior to adjusting the door and/or activation of the 

 

  coldroom, these must be removed.

3.8   Adjusting the hinges

 

   

Important!

 

  lf the magnetic gasket profile does not fit properly 

 

  around the whole periphery of the door and the sealing

 

  profile does not lie flush on the threshold or the flooring

 

  on the inside, deviations can be adjusted for in three

 

  ways on the door hinges.

 

 

Remove covering caps (N) from the door hinges. Open the

 

  door and insert a nail, a small screwdriver or something (M)

 

  similar diagonally into the opening (K) with the cap in order 

 

  to release the cap locking.

 

  After releasing the screw (P) or (R), the door can be adjusted

 

  horizontally or depthwise.

 

  For vertical adjustment, turn the screws of the rising hinges 

 

  (T) so that the door reaches the wanted height (see image). 

 
 

  The non-rising hinge can be mounted on the left or on the 

 

  right side. It has the same screw (T) at the top and at the 

 

  bottom. For vertical adjustment, turn the screw (T) so that 

 

  the door is in the wanted height.  For that, first release the 

 

  upper screw (T) and then adjust the hinge turning the lower 

 

  screw (T). Finally, fasten the upper screw (T) so that the 

 

  hinge can still be moved easily. 

3.9   Door lock fastener

 

 

The door lock fastener (V) of the hairpin lock has been 

 

  factory-fitted at the plant. After assembly and adjustment 

 

  of the door, the fit of the lock behind the door lock fastener 

 

  should be tested. 

 

  lf adjustment is necessary, loosen screws (U), and insert 

 

  support (W) if necessary, adjust door lock fastener and 

 

  tighten screws again.

 

  Check that see if the door has a tight seal. After that, drill

 

  holes with a 3.7 mm drill and fix the fastener additionally

 

  with the screws provided (X).

M

P U

N

R

P

M

K

M

N

R

T

K

W

X

U

V

Summary of Contents for TectoCell Compact 100

Page 1: ...o Any work on the electrical parts of the coldroom must be assembling or commissioning the unit Your specialist done by qualified electricians The plug must be separated refrigeration technician will...

Page 2: ...embly 3 1 Connecting the coldroom panels 3 2 Assembly of the flooring panels 3 3 Assembly of the wall panels 3 4 Assembly of the door 3 5 Assembly of the ceiling panels 3 6 Assembly of the door thresh...

Page 3: ...or installing a ceiling refrigeration unit or other elements such as hanging rails pipes etc additional support must be provided during assembly Attention During installation of the refrigeration uni...

Page 4: ...ial prop construction Before starting to install the device check the dimensions of the intended place of installation With this also the right angularity has to be checked by diagonal measurement lt...

Page 5: ...a distance of 200 to 300 mm from each other Ensure that the joins B and the exterior edges A are placed exactly on the flooring gratings lf there is unevenness in the flooring the flooring gratings mu...

Page 6: ...be done carefully to prevent any and all penetration by water or contamination The individual coldroom elements are labelled The respec tive position of each coldroom element can be ascertained by com...

Page 7: ...g panels with one or two sided connections fill the points marked on the drawing with sealant Do not place weight on the panel to be assembled Push the flooring panels together and tighten the externa...

Page 8: ...the side section of the door frame or on the wall before installing the ceiling elements During installation ensure that the evaporator fan does not blow onto the door leaf and the pressure compensat...

Page 9: ...the cap in order to release the cap locking After releasing the screw P or R the door can be adjusted horizontally or depthwise For vertical adjustment turn the screws of the rising hinges T so that t...

Page 10: ...nels which are screwed onto the floor of the room in which the coldroom is assembled These are constructed such that they form a seal with the floor of the building During assembly the wall panels are...

Page 11: ...Open the distributor s lead through opening and insert enclosed grommet Insert the power supply lead into the grommet and secure to L1 N and PE in the distributor Connect to power supply The power le...

Page 12: ...m the side of the outside handle using a 2 5 mm hexagon key L Insert key H into the cylinder F turn to the horizontal position with turn and remove cylinder lock with key Install in reverse sequence T...

Page 13: ...eaning the refrigeration unit and the coldroom should be cut off from the power supply Remove the plug from the power supply during such work and secure against the plug being reinserted or switch off...

Page 14: ...adiation from the sun will increase power use Allow warm food to cool down to room temperature before placing it the coldroom Avoid keeping the door open for longer than necessary Monitor temperature...

Page 15: ...ils of this technical documents serve for description Consents regarding the availability of certain features or regarding a certain purpose always require a special written agreement Page 15 GB Right...

Page 16: ...Middle East FZE Telephone 971 43724247 refrigeration viessmann ae www viessmann ae United Kingdom Viessmann Refrigeration Systems Limited Telephone 44 1952 457157 sales viessmann coldtech co uk www v...

Reviews:

Related manuals for TectoCell Compact 100