regarding a certain purpose always require a special written agreement.
Page 6 GB
Right reserved to make technical changes!
GB
3. Coldroom assembly
Important!
The panels are provided with seal at the plant
- do not damage!
When transporting or moving the elements, do not
grasp them by the overlap of the spring side or
in their groove. Always hold the elements at the bot
tom, to prevent the sheets from coming loose.
All joining work is to be done carefully to prevent any
and all penetration by water or contamination.
The individual coldroom elements are labelled. The respec-
tive position of each coldroom element can be ascertained
by comparing the label on the coldroom, the provided
drawing and BOM.
3.1 Connecting the coldroom panels
The coldroom panels are connected using foamed in
eccentric cam locks. These are activated from the interior of
the coldroom. Prior to assembly check that all the cam
locks are open by turning them to the left. The cam locks
have a pulling distance of 12 mm. lf the distance between
the coldroom panels is greater than 12 mm during
assembly, the eccentric locks will not clamp in place. In this
case, open the cam locks again and push the panels
together, and then clamp the locks shut again.