6.1 DHW cylinder Vitocell 100-V
DHW cylinder Vitocell 100-V
DHW cylinder Vitocell 100-V
Cylinder capacity (litres)
160
200
300
500
750
1000
Part no.
3003702
3003703
Z002575
Z002576
Z004044
Z004045
Delivered condition
Vitocell 100-V, type CVA
160, 200 and 300 litre capacity
DHW cylinder made from steel with Ceraprotect enamel coating for
DHW heating.
■ Welded-in sensor well for cylinder temperature sensor or thermo-
stat
■ Adjustable feet
■ Protective magnesium anode
■ Fitted thermal insulation
Colour of the epoxy-coated sheet steel casing: Vitosilver.
DHW cylinders with 160, 200 and 300 litre capacity are also available
in white.
Vitocell 100-V, type CVA
500 litre capacity
DHW cylinder made from steel with Ceraprotect enamel coating for
DHW heating.
■ Welded-in sensor well for cylinder temperature sensor or thermo-
stat
■ Adjustable feet
■ Protective magnesium anode
Packed separately:
■ Removable thermal insulation; the colour of the plastic-coated ther-
mal insulation is Vitosilver
Vitocell 100-V, type CVA
750 and 1000 litre capacity
DHW cylinder made from steel with Ceraprotect enamel coating for
DHW heating.
■ Thermometer
■ Welded-in sensor well for cylinder temperature sensor or thermostat
■ Adjustable feet
■ 2 protective magnesium anodes
Packed separately:
■ Removable thermal insulation; the colour of the plastic-coated ther-
mal insulation is Vitosilver
Specification
For DHW heating
in conjunction with boilers and district heating sys-
tems, as option with electric heater as accessory for DHW cylinders
with 300 and 500 l capacity.
Suitable for the following systems:
■ DHW temperatures up to
95 °C
■ Heating water flow temperature up to
160 °C
■ Operating pressure on the
heating water side
up to
25 bar
(2.5 MPa)
■ Operating pressure on the
DHW side
up to
10 bar (1.0 MPa)
Cylinder capacity
l
160
200
300
500
750
1000
DIN register number
9W241/11–13 MC/E
Continuous output
For DHW heating from
10 to 45 °C
and a
heating water
flow tempera-
ture of ... at the heating water
throughput stated below
90 °C
kW
40
40
53
70
123
136
l/h
982
982
1302
1720
3022
3341
80 °C
kW
32
32
44
58
99
111
l/h
786
786
1081
1425
2432
2725
70 °C
kW
25
25
33
45
75
86
l/h
614
614
811
1106
1843
2113
60 °C
kW
17
17
23
32
53
59
l/h
417
417
565
786
1302
1450
50 °C
kW
9
9
18
24
28
33
l/h
221
221
442
589
688
810
Continuous output
For DHW heating from
10 to 60 °C
and a
heating water
flow tempera-
ture of ... at the heating water
throughput stated below
90 °C
kW
36
36
45
53
102
121
l/h
619
619
774
911
1754
2081
80 °C
kW
28
28
34
44
77
91
l/h
482
482
584
756
1324
1565
70 °C
kW
19
19
23
33
53
61
l/h
327
327
395
567
912
1050
Heating water throughput
for the stated con-
tinuous outputs
m
3
/h
3.0
3.0
3.0
3.0
5.0
5.0
Standby heat loss q
BS
at a temp. differential of 45 K (actual values to
DIN 4753-8).
kWh/
24 h
1.50
1.70
2.20
2.50
3.50
3.90
Dimensions
DHW cylinder
PYROMAT ECO
37
5822 546 GB