41
Value, ad-
dress 00: ...
Description
9
One heating circuit without mixer A1 (heating circuit 1), one heating circuit with mixer M2 (heat-
ing circuit 2) and one heating circuit with mixer M3 (heating circuit 3), without DHW heating
(code is set automatically)
10
One heating circuit without mixer A1 (heating circuit 1), one heating circuit with mixer M2 (heat-
ing circuit 2) and one heating circuit with mixer M3 (heating circuit 3), with DHW heating (code is
set automatically)
Coding in the delivered condition
Possible change
Internal circulation pump function
51:0
When there is a heat demand, the
internal circulation pump always
starts
51:1
System with low loss header:
The internal circulation pump only
starts upon heat demand if the burn-
er is running.
The circulation pump stops on expiry
of the run-on time.
51:2
System with heating water buffer
cylinder:
The internal circulation pump only
starts upon heat demand if the burn-
er is running.
The circulation pump stops on expiry
of the run-on time.
Subscriber no.
77:1
LON subscriber number
77:2
to
77:99
LON subscriber number adjustable
from 1 to 99:
1 - 4 = Boiler
5 = Cascade
10 - 97 = Vitotronic 200-H
98 = Vitogate
99 = Vitocom
Note
Allocate each number
only
once.
Detached house/apartment building
7F:1
Detached house
7F:0
Apartment building
Holiday program and time program
for DHW heating can be set sepa-
rately
Lock-out control
8F:0
Operation enabled in standard and
extended menu.
Note
The code is only enabled when
you exit the service menu.
8F:1
Operation locked out in standard
and
extended menu.
Emissions test mode can be ena-
bled.
8F:2
Operation enabled in standard
menu, but locked out in extended
menu.
Emissions test mode can be ena-
bled.
Codes
Coding level 1
(cont.)
5686 293 GB
Codes