70
Note
Do
not
change the setting of annular gap
A
.
Cleaning or replacing filters in the extract air vent
!
Please note
Dust will settle inside the ductwork if the
mechanical ventilation system is operated with-
out filters. This increases the air pressure drop.
Isolate the ventilation unit from the power supply
or disconnect the power supply plug before
removing the filter from the extract air vent.
2.
1.
Fig. 109
Cleaning the kitchen extract air vent
!
Please note
When the mechanical ventilation system is oper-
ating without a filter, dust and grease settles in
the ductwork. This increases the air pressure
drop.
Isolate the ventilation unit from the power supply
or disconnect the power supply plug before
removing the filter from the kitchen extract air
vent.
3.
B
A
1.
2.
Fig. 110
A
Grease filter
B
Locking plug
3.
Clean the grease filter with water and detergent or
in the dishwasher.
Commissioning, inspection, maintenance
Cleaning the ductwork
(cont.)
5831646