42
Wall installation: Flat duct in wall
C
200 - 300
B
A
Fig. 50
A
Supply air vent, extract air vent, kitchen extract air
vent or wall/ceiling air vent
B
Diverter
—
round to flat
C
Flat duct
Wall installation: Flat duct in suspended ceiling
A
D
B
C
200 - 300
Fig. 51
A
Suspended ceiling
B
Flat duct
C
Vent connection, straight
D
Supply air vent, extract air vent, kitchen extract air
vent
Installing in the ceiling
B
C
D
E
A
Fig. 52
A
Screed
B
Impact sound insulation
C
Flat duct
D
Diverter
—
round to flat
E
Supply air vent, extract air vent, kitchen extract air
vent
Floor installation
≥
140
A
B
C
D
Fig. 53
A
Screed
B
Impact sound insulation
C
Flat duct with compensating insulation: 60 mm
D
Floor outlet
Fitting the supply/extract air vents
Installation versions, supply air/extract air vents
5831646
Installation