Vertical outlet for sloping or flat roofs
(cont.)
Installation
Balanced flue roof outlet
Please note
Ensure the specified minimum lengths
above the roof are observed.
Never trim roof outlets outside the roof.
n
Install pipe outlets for Klöber roof tiles,
universal roof tiles or flat roof collars in
accordance with manufacturer’s details.
n
Integrate the flat roof collar into the roof
skin according to the flat roof guidelines.
n
Ceiling opening (min. diameter):
-105 mm (system size 60)
-130 mm (system size 80)
-160 mm (system size 100).
n
Secure the roof outlet with a clamp only
after the installation has been completed.
n
Position the roof outlet from the top onto
tiles or the flat roof collar.
n
Connect the balanced flue from below.
24
5458 035 GB
!
Summary of Contents for Flue gas system
Page 36: ...5458 035 GB 35 ...