24
Fitting the connection set
The connection set is supplied in a separate cardboard
package.
2.
1.
3x
A
B
C
3.
3 x 24 Nm
Fig. 12
A
Heating return R
¾
B
Gas shut-off valve
C
Heating flow R
¾
1.
Remove the sealing plug.
2.
Fit the connection set.
Note
Gasket colours
■
Gas connection: White
■
Connections on the heating water side: Green
3.
Depending on the position of the on-site mains
connection, route the cable connected to the mains
distributor box sideways out of the appliance.