![Viessmann E00T Installation And Service Instructions For Contractors Download Page 90](http://html.mh-extra.com/html/viessmann/e00t/e00t_installation-and-service-instructions-for-contractors_1017911090.webp)
90
fÖ
Power supply
jF
PlusBus
lA
CAN bus
lH
No function
aBH
Power supply for accessories
A
From mains distributor box
B
To the fuel cell
C
To the electricity meter
D
Terminator
EM-MX mixer extension kit (ADIO electronics module)
Fig. 63
A1
EM-MX mixer extension kit (ADIO electron-
ics module)
A2
PCB HMU heat management unit
P1
No function
P3
gS
3-way mixing valve, heating water buffer cyl-
inder
PWM1
No function
S1
Rotary switch
TS1
?
Raised system return temperature sensor
TS2
?
System return temperature sensor
TS3
%
Cylinder temperature sensor, middle
F1
Fuse
K1 to K3 Relay
T1
Switching mode power supply
X...
Electrical interfaces
fÖ
Power supply
fÖ
A
Power supply for accessories
jF
PlusBus
Connection and wiring diagrams
HMU heat management unit connection diagram
(cont.)
5839343
Appendix
Summary of Contents for E00T