Information regarding the electrical connections
■
The total output of all components connected directly
to the heat pump control unit (e.g. pumps, valves,
signalling equipment, contactors) must not exceed
1000 W.
If the total output
≤
1000 W, the individual rating of a
component (e.g. pump, valve, signalling equipment,
contactor) can be greater than specified. However,
the breaking capacity of the corresponding relay
must not be exceeded: See following chapter.
■
The terminals may have been pre-allocated at the
factory.
If 2 components are connected to the same terminal,
press both cores together in a
single
wire ferrule.
■
The KM-BUS wires are interchangeable.
■
The Modbus wires are
not
interchangeable.
■
The neutral and earth conductors of all components
are connected to terminals X2.N and X1.
?