74
Compressor 2
Parameter
Code
Delivered condition Commission-
ing
Maintenance/
Service
"Enable compressor"
5100
0
"Enable use of compressor stage"
5112
15
"Primary source output"
5143
0
"Output compressor stage"
5130
Rated heating output
according to type
plate
External heat generator
Parameter
Code
Delivered condition Commission-
ing
Maintenance/
Service
"Enable external heat source"
7B00
0
"Priority ext. heat source/Instant. heating
water heater"
7B01
1
"Dual mode temperature external heat
source"
7B02
100 (
≙
10 °C)
"Enable external heat source for central
heating"
7B0C
1
"Enable external heat source for DHW
heating"
7B0D
0
"Shutdown limit, heat pump dual mode"
7B0F
–
500 (
≙
–
50 °C)
"Enable boiler water temperature sen-
sor"
7B11
1
DHW
Parameter
Code
Delivered condition Commission-
ing
Maintenance/
service
"Set DHW temperature"
6000
500 (
≙
50 °C)
"Min. DHW temperature"
6005
100 (
≙
10 °C)
"Max. DHW temperature"
6006
600 (
≙
60 °C)
"Hysteresis DHW temperature heat
pump"
6007
50 (
≙
5 K)
"Hysteresis DHW temperature booster
heater"
6008
100 (
≙
10 K)
"Start optimisation for DHW heating"
6009
0
"Stop optimisation for DHW heating"
600A
0
"Set DHW temperature 2"
600C
600 (
≙
60 °C)
"Temperature sensor at bottom of DHW
cylinder"
600E
0
"Enable booster heaters for DHW heat-
ing"
6014
0
"Enable electric heaters for DHW heat-
ing"
6015
1
"Priority DHW heating with combi cylin-
der"
6016
0
"Start attempts for DHW after high pres-
sure shutdown"
6017
1
Commissioning/service reports
Control parameter report
(cont.)
5787 232 GB
Appendix