54
Adjusting the set room temperature
Standard room temperature
90
-20
26 + 20
A
C
D
E
B
Fig. 52
Example 1: Adjusting the standard room tem-
perature from 20 to 26 °C
A
Boiler water temperature or flow temperature in °C
B
Outside temperature in °C
C
Set room temperature in °C
D
Heating circuit pump "OFF"
E
Heating circuit pump "ON"
Adjustment of the standard room temperature:
Operating instructions
Reduced room temperature
+20 14 5
90
-20
D
E
A
C
B
Fig. 53
Example 2: Adjusting the reduced room tem-
perature from 5 °C to 14 °C
A
Boiler water temperature or flow temperature in °C
B
Outside temperature in °C
C
Set room temperature in °C
D
Heating circuit pump "OFF"
E
Heating circuit pump "ON"
Adjustment of the reduced room temperature:
Operating instructions
Connecting the control unit to WiFi
Note
Vitoconnect 100, OPTO1 (accessories) required.
For installation and commissioning: See the separate
installation and commissioning instructions.
Linking the control unit to the LON
The LON communication module must be plugged in.
Note
The data transfer via LON can take several minutes.
Example: Single boiler system with Vitotronic 200-
H and Vitocom 200
Set the LON subscriber numbers and further functions
via code 2 (see the following table).
Note
The same subscriber number must
not
be allocated
twice within the LON.
Only one Vitotronic
may be programmed as fault
manager.
Commissioning, inspection, maintenance
Adjusting the heating curves
(cont.)
6136330