35
For connecting the DHW side, observe DIN 1988 and DIN 4753 .
M
A
N
B
C
L
K
D
H
O
N
H
P R H M O
H
G
F
E
A
DHW
B
DHW circulation pump
C
Spring-loaded check valve
D
Heat pump connecting chamber
(plan view)
E
Expansion vessel, suitable for drink-
ing water
F
Visible discharge pipe outlet point
G
Safety valve
H
Shut-off valve
K
Flow regulating valve
L
Pressure gauge connection
M
Non-return valve/pipe separator
N
Drain valve
O
Cold water
P
Drinking water filter
R
Pressure reducer
Information on drinking water filter
According to DIN 1988-2, a drinking
water filter should be installed in systems
with metal pipework. We also recom-
mend the installation of a drinking water
filter when using plastic pipes, according
to DIN 1988, to prevent contaminants
entering the DHW system.
Safety valve
Protect the DHW cylinder with a safety
valve against unduly high pressure.
Installation sequence
Connections on the DHW side
5782 201 GB
Installation