Ventilation
Parameter
Code
Delivered condi-
tion
Commis-
sioning
"Vitovent enable"
7D00
0
"Enable preheater bank electric"
7D01
0
"Enable reheater bank hydraulic"
7D02
0
"Enable humidity sensor"
7D05
0
"Enable CO2 sensor"
7D06
0
"Extract air temperature with standard
ventilation"
7D08
200 (
≙
20 °C)
"Flow rate reduced ventilation"
7D0A
120 m
3
/h
"Flow rate nominal ventilation"
7D0B
170 m
3
/h
"Flow rate intensive ventilation"
7D0C
215 m
3
/h
"Min. supply air temperature for by-
pass"
7D0F
160 (
≙
16 °C)
"CO2 value for fan start"
7D18
800 ppm
"Humidity value for fan start"
7D19
65 %
"Interval time frost protection ventila-
tion"
7D1A
15 min
"Intensive ventilation duration"
7D1B
120 min
"Actual source room temperature"
7D1D
1
"Heating circuit for blocking bypass
damper"
7D21
7
"Control voltage matching"
7D27
0 (
≙
0 V)
"Fan for control voltage matching"
7D28
0
Photovoltaic systems
Parameter
Code
Delivered condi-
tion
Commis-
sioning
"Enable own energy consumption
PV"
7E00
0
"Enable own energy consumptn for
set DHW temperature 2"
7E10
0
"Enable own energy consumption for
DHW heating"
7E11
0
"Enable own energy consumptn for
heating water buffer cyl."
7E12
0