60
Function/system components
Code
Setting
Group
Operation with LPG
82:1
"General"
System
with
DHW circulation pump:
DHW circulation pump connected at internal H1 or H2 extension
—
—
System version 2
One heating circuit with mixer M2 and low loss header
1
M
3
4
5
6
7
2
9
8
wP
wQ
Fig. 53
1
Vitodens 242-F
2
Outside temperature sensor
3
Heating circuit with mixer M2
4
Temperature limiter to restrict the maximum tem-
perature of underfloor heating systems
5
Flow temperature sensor M2
6
Heating circuit pump M2
7
Extension kit for one heating circuit with mixer M2
8
Low loss header
9
Flow temperature sensor, low loss header
wP
Solar collectors
wQ
Collector temperature sensor
Function/system components
Code
Setting
Group
Operation with LPG
82:1
"General"
System with
only
one heating circuit with mixer, with extension kit for
mixer with DHW heating
00:4
"General"
System
with
DHW circulation pump:
DHW circulation pump connected at internal H1 or H2 extension
—
—
System
with
low loss header
04:0
"Boiler"
Commissioning, inspection, maintenance
Matching the control unit to the heating system
(cont.)